HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

domainID=0
hostMode=Standard
hostModeOption=
displayName=CL3-E-0
domainType=0
nickname=3E-G00
An instance of HostStorageDomain
objectID=*****
portID=9
portName=CL3-E
domainID=1
hostMode=Standard
hostModeOption=
displayName=CL3-E-1
domainType=0
nickname=HP0900
List of 1 WWN elements:
An instance of WWN
WWN=21.00.00.E0.8B.0C.39.2F
nickname=
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=PortController)
GetStorageArray (subtarget=PortController) obtains the information about port controllers.
Parameters
Table 63 GetStorageArray (subtarget=PortController) command parameters
DescriptionStatusParameter name
Specify PortController.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Controller ID of the port controller in the storage system
Specify this parameter when you want to obtain information about
a specific port controller. If you specify this parameter, you must
also specify the model and serialnum parameters. If
controllernum and controllername are omitted, port
controller information is obtained for the specified storage system.
Do not specify controllernum and controllername at the
same time. If they are specified at the same time, an error occurs.
Optional
controllernum
Command reference188