HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

#1
For P9500, you need to specify at least one of the following parameters: threshold,
threshold2, threshold2mode, overprovisioningwarning, overprovisioninglimit,
adddevnums, tiercontrol, automigration, migrationinterval, monitorstarttime,
monitorendtime, or monitoringmode.
#2
For XP24000/XP20000, you need to specify at least one of the following parameters: threshold,
overprovisioningwarning, overprovisioninglimit, or adddevnums.
#3
If you specify threshold values for overprovisioningwarning and overprovisioninglim-
it, two levels of warnings related to the over-provisioning percent can be issued. For
XP24000/XP20000, these threshold values are specific to and managed by the Device Manager
server.
#4
The over-provisioning percent is the percentage of the total size of all THP/Smart volumes with
respect to the THP/Smart pool size. For example, if the THP pool size is 500 GB and the total
size of all THP volumes is 400 GB, the threshold value is 80 %.
#5
For details about the values used when tiercontrol or automigration setting is changed
from disable to enable, and migrationinterval, monitorstarttime, monitorend-
time, and monitoringmode are omitted, see AddPool on page 78.
#6
There must be an interval of at least one hour between the times specified for monitorstarttime
and monitorendtime. The same time cannot be specified for monitorstarttime and
monitorendtime.
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
poolid
Obtain this value from the execution result of the GetStorageArray (subtarget=Pool)
command. In the execution result of this command, the poolID value appears under An in-
stance of Pool. Use this value to specify the poolid parameter.
adddevnums
Obtain this value from the execution result of the GetStorageArray (subtarget=Logic-
alUnit, lusubinfo=LDEV) command. Execute this command by specifying only the model
and serialnum parameters, LogicalUnit for the subtarget parameter, and LDEV for the
lusubinfo parameter. In the execution result of this command, the devNum value of LogicalUnit
appears under An instance of LogicalUnit. Use the devNum value of a logical unit that
satisfies the conditions to be used as a pool volume in a THP/Smart pool, to specify the ad-
ddevnums parameter.
Command execution example 1
In this example, the ModifyPool command expands the THP pool whose pool ID is 5 (poolid: 5) in
the storage system (serialnum: 53039, model: P9500).
CLI Reference Guide 221