HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

DescriptionStatusParameter name
Snapshot group name
Use a maximum of 32 bytes for a group name. The group name
cannot begin with a hyphen (-).
For details about the characters that can be used group names,
follow the rules for RAID Manager.
This parameter is ignored if the snapshotgroupid parameter
is specified.
Optional
snapshotgroup-
name
Type of operation that is to be executed with the copy pair
Specify FastSnap.
Required
replication-
function
Parameter values to obtain in advance
hostid
Execute the GetHost command with the host name indicated below specified for the hostname
parameter.
When managing copy pairs by using local management
Specify the host on which the raidcom command for RAID Manager (raidcom command) that
manages the P-VOL is installed.
The execution results of the GetHost command displays the hostID value under An in-
stance of Host. Use the hostID value to specify the hostid parameter.
When managing copy pairs by using central management
Specify the host that centrally manages copy pairs.
The execution results of the GetHost command displays the hostID value under An in-
stance of Host. Use the hostID value to specify the hostid parameter.
pvoldevnum and svoldevnum
Execute the GetHost command with LogicalUnit specified for the subtarget parameter
and the name of the host that recognizes the P-VOL or the S-VOL specified for the hostname
parameter.
The execution result of the GetHost command displays the objectID value (object ID of the
logical unit) and the devNum value under An instance of LogicalUnit.
If you specify a host that recognizes the P-VOL, use the devNum value of a logical unit (under An
instance of LogicalUnit) that will be used as the P-VOL to specify the pvoldevnum
parameter. When you specify these parameters, record the objectID value.
If you specify a host that recognizes the S-VOL, use the devNum value of a logical unit (under An
instance of LogicalUnit) that will be used as the S-VOL to specify the svoldevnum
parameter.
pvolarraytype and pvolserialnum
Execute the GetStorageArray (subtarget=LogicalUnit) command with LogicalUnit
specified for the subtarget parameter and the object ID of the logical unit used as the P-VOL
(the objectID value recorded when the pvoldevnum value was obtained) specified for the
objectID parameter.
The execution result of the GetStorageArray (subtarget=LogicalUnit) command displays
the specified object ID under An instance of LogicalUnit. See the values of arrayType,
displayArrayType, and serialNumber under An instance of StorageArray that
Command reference352