Obtain this value from the execution result of the GetStorageArray (subtarget=Port)
command. In the execution result of this command, the displayName value appears under An
instance of Port. Use this value to specify the portname parameter.
nickname
Obtain this value from the execution result of the GetStorageArray (subtarget=Port)
command. Execute this command by specifying only the model and serialnum parameters,
Port for the subtarget parameter, and HostStorageDomain for the portsubinfo para-
meter. In the execution result of this command, the value of nickname appears as An instance
of HostStorageDomain.
Command execution example
hdvmcli AddHostStorageDomain -o "D:\logs\AddHostStorageDomain.log"
"serialnum=10037" "model=XP24000" "port=3" "domain=15" "hostmodeoption=7;40"
Command execution result
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 HostStorageDomain elements:
An instance of HostStorageDomain
objectID=*****
portID=3
portName=CL7-A
domainID=15
hostMode=Standard
hostModeOption=7;40
displayName=CL7-A-15
domainType=0
nickname=HCMD0030f
*****: The value is encoded by the CLI.
AddLabel
AddLabel adds a label to a logical unit.
Parameters
Table 24 AddLabel command parameters
DescriptionStatusParameter name
Serial number of the storage systemRequired
serialnum
Model of the storage systemRequired
model