HP StorageWorks P9000 Performance Advisor Software v5.4 Troubleshooting and FAQs Guide (T1789-96336, April 2012)

Cause
An Unknown Host error is displayed when you view the host agent details in the Host Information
table in P9000 Performance Advisor. This is because, the host name might not be resolved.
Resolution
Do the following:
Ensure that the host is up and running. Try to ping the host (command prompt>ping <hostname>).
The host browser-side system is able to resolve the host name. Try to ping the host (command
prompt>ping <hostname>).
If the second option fails, you must set the DNS configuration. To configure, do the following:
1. Go to Start > Control Panel > Network Connections.
2. Right click Local Area Connection, select Properties.
3. On the General tab, double-click Internet Protocol (TCP/IP).
The Internet Protocol (TCP/IP) properties Window is displayed.
4. Click the Advanced tab.
The Advanced TCP/IP Settings window is displayed.
5. On the DNS tab, select Append DNS suffixes.
6. Add host name suffix.
7. Click OK to save the settings.
Cause
An incompatible browser version is used to launch P9000 Performance Advisor.
Resolution
Correct the browser version used to launch P9000 Performance Advisor. Also, configure your IE
browser to allow pop-ups, so that P9000 Performance Advisor functions properly. For the list of
supported IE versions, see the HP StorageWorks P9000 Performance Advisor Software OS Support
Matrix.
After you are able to view the host agent records, refresh the Host Information table on the Array
View screen Monitoring > Array View > Host Information. For more information, see the HP
StorageWorks P9000 Performance Advisor Software User Guide. For document download location,
see Related information on page 97.
Data collection failure after installing or upgrading P9000 Performance Advisor
P9000 Performance Advisor might not collect configuration or performance data for the XP and the
P9000 disk arrays though the installation, or upgrade is completed without any errors.
Cause
The Windows or UNIX host agent is unable to contact P9000 Performance Advisor and the host agent
might not appear in the Host Information table in P9000 Performance Advisor.
Troubleshooting P9000 Performance Advisor issues22