HP XP P9000 Performance Advisor Software v6.0 User Guide

“Stopping performance data collection” (page 66)
“Deleting performance data collection schedule” (page 68)
“Starting real-time performance data collection” (page 319)
Enabling performance collection schedules for automatic updates
You can enable the performance data collection schedules to automatically collect the performance
data for newly discovered RAID groups and ports. The new RAID groups and ports in an XP or a
P9000 disk array are discovered during the scheduled configuration data collection. They are
automatically appended to the existing list of RAID groups and ports in the corresponding
performance data collection schedule, which is enabled to collect performance data for the new
components. The newly discovered components are added to only those performance data collection
schedules that are enabled for automatic updates. HP XP P9000 Performance Advisor collects data
for new RAID groups and ports from the subsequent data collection cycle.
The new components can also comprise of virtual volumes, such as ThP, snapshot, continuous
access journals, and the external RAID groups. The virtual volumes cannot be split across two
schedules. They are automatically added to only those performance data collection schedules that
are already collecting the performance data for these virtual volumes. It is irrespective of whether
the performance data collection schedule is enabled to receive automatic updates.
For a schedule to automatically collect data for the new set of RAID groups and ports, select the
Add new RGs and Ports to the schedules that have RG and Port components enabled check box
while creating a performance data collection schedule. The following table provides scenarios on
when a schedule can be enabled for automatic updates.
What happens...Automatic updatesScenarios
The newly discovered RAID groups and
ports are automatically appended to
Enabled Schedule 1 for automatic
updates.
One schedule created (Schedule 1)
the existing list for which performance
data collection is scheduled. The
performance data collection continues
for the new components also.
The newly discovered RAID groups and
ports are not appended to the existing
Disabled Schedule 1 for automatic
updates.
list of RAID groups and ports. You have
to modify the performance data
collection schedule later to add or
remove components from Schedule 1.
The newly discovered RAID groups and
ports are automatically appended to
Enabled Schedule 1 for automatic
updates.
Two schedules created (Schedule 1
and Schedule 2)
the existing list for which Schedule 1 is
in progress. The performance data
collection continues for the new
components also. The newly discovered
RAID group and port components that
are not selected in any performance
data collection schedule are added to
the appropriate schedule.
Schedule 2 is automatically disabled
for automatic updates, as Schedule 1
is already enabled to receive automatic
updates.
Hence, you must edit the schedule
manually to add or remove components
from Schedule 2. However, if Schedule
1 is not enabled for automatic updates,
64 Collecting configuration and performance data