HP P9000 for Business Continuity Manager Software Messages Abstract This guide describes the error messages and error codes that are produced by HP Business Continuity Manager Software including: HP Business Continuity Manager, HP Business Continuity Manager Basic, HP Business Continuity Manager Extended CT Group, and HP Business Continuity Manager Universal Replicator 4x4 Extended CTG.
© Copyright 2007, 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Edition Date Description Ninth May 2011 This document revision applies to Business Continuity Manager version 6.60 and higher. Tenth September 2011 This document revision applies to Business Continuity Manager version 6.61 and higher.
Contents 1 Messages..................................................................................................5 Message Format.......................................................................................................................5 Message Output Format........................................................................................................5 Notations Used to Describe Messages....................................................................................
1 Messages This chapter describes the messages that are issued by Business Continuity Manager: • “Message Format” (page 5) • “Message Output Destination” (page 7) • “List of Messages” (page 7) • “Multi-line Messages Output to SYSTSPRT” (page 157) • “User Completion Codes” (page 161) • “Identifying the Volume to Be Processed” (page 162) The GUI illustrations in this guide were created using a Windows computer with the Internet Explorer browser.
• YKD: YKDELETE • YKE: YKEWAIT • YKF: YKFREEZE • YKG: YKHDAX (an internal program of YKLOAD) • YKH:YKH2B • YKJ: YKIMPORT, or YKEXPORT • YKK:YKINSCHK • YKL: YKLOAD • YKM: YKMAKE, messages displayed in the ISPF panel, or ISPFLOG • YKN: YKRUN • YKP: YKSTATS • YKQ: YKQUERY • YKR: YKRESYNC • YKS: YKSTORE • YKT: YKALCSVC, or YKSETENV • YKU: YKSUSPND • YKV: YKRECVER • YKW: YKWATCH • YKX: YKBLDCMD, YKDELCMD, or YKQRYDEV • YKY: Business Continuity Manager agent • YKZ: All com
Message Output Destination The following destinations appear in messages issued by Business Continuity Manager: • MSG: Message structure • TSO: TSO/E terminal • CON: Console • SYS: SYSLOG • PRT: SYSPRINT or SYSTSPRT • LOG: ISPF log • ISPF: ISPF panel# • XML: HP P9000 Command View Advanced Edition Software log and window # If MSGID ON is specified using the ISPF system command, the message ID and message text are displayed in the ISPF panel.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8008E CON BCM Monitor initialization failed: termination-code. An attempt to start BCM Monitor failed because of the reason indicated in a preceding message that was output to either the console or dd SYSTSPRT. Contact the center administrator.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8017E CON Invalid command: command-name. There is an error in the command-name command. Operand is incorrect: command-name. There is an error in an operand of the command-name command. The number of commands of execution waiting exceed the upper limit: command-name.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions return-code • 20: EXEC processing failed. • 20021: There was an error in the parameter list that was passed to IRXJCL. YK8026E CON IRXINIT module error: code=return-code, R0=abnormal-termination -ode-and-reason-code -or-abnormal-termination, PARM7=reason-code.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text YK8028E CON BCM Monitor function abend: code=Sxxx Uxxxx Explanation and Recommended Actions The main task or subtask terminated abnormally during BCM Monitor processing. If the task cannot be recovered, BCM Monitor abended-module=module-name will stop. C-Date=module-creation-date Contact the center administrator.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. label Label at which BCM Monitor stops YK8041I PRT CON time BCM Monitor will stop at the end of monitor cycle. BCM Monitor will stop at the end of a cycle. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions time Message output time This is only displayed when the output destination is SYSTSPRT. YK8047I PRT CON time Set MONITOR=-status for Copy Group 'cgid'. BCM Monitor set the monitoring status of the copy group cgid to the status status. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text YK8055I PRT CON time BCM Monitor will pause now for ‘sleep-time’ minutes. Explanation and Recommended Actions BCM Monitor will go to sleep because the PAUSE action was executed. Entering the WAKEUP command resumes copy group monitoring before the sleep time of sleep-time has elapsed.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. nnn (decimal number) Return code of the FREEMAIN macro YK8075E PRT time Parameter syntax error : file : rec#. There is a syntax error in a parameter. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions param-name Name of the required parameter YK8079E PRT time CGID parameter must be specified first : rec#. Specify the CGID parameter at the beginning of the copy group parameters in the YKMONCG file. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Copy group ID specified in the ACTION parameter YK8084E PRT time The continuation symbol The continuation symbol was specified for the final record. can not be specified in the time final record : file. Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions The number of lines equal to the number of messages included in the message structure are displayed. YK8221I PRT CON time YKEWAIT (RC=4) : TIMEOUT value (timeout) reached. The YKEWAIT command timed out before the transition to the expected group status.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. YK8301I PRT CON time Not all volumes are in 'status'. action requested. The action identified by action will be executed because there is a volume that is not in the status identified by status.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions GROUP STATUS : status MATCHING% : match REVERSED% : rev% prefix ATTIME(GMT) : attimeSTATUS : attms simplexct Prefix Number of copy pairs in SIMPLEX status pendingct Number of copy pairs in PENDING status duplexct Number of copy pairs in DUPLEX status suspendallct Number of copy pairs in SUSPEND status otherct Number of
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Copy direction • >: Primary-to-secondary • <: Secondary-to-primary sdevn Secondary device number status Copy pair status match Copy pair matching percentage ctid Consistency group ID or master journal group ID sub-ctid Restore journal group ID ctdelta Consistency delta value for each consistency group cttime Consistency time
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8317I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the TCA copy group.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8318I See “YK8318I PRT” (page 160). N/A YK8319I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the Cnt Ac-J Z copy group.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8321I PRT CON time Some volumes are in a Some volumes are in the TRANSITION status. 'TRANSITION' status. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8401I PRT CON time Check Startup Status of BCM Monitor will start checking the status of the copy group Copy Group 'cgid'. identified by cgid. time Message output time This is only displayed when the output destination is SYSTSPRT.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8410I PRT CON time ---- date ---- The date is displayed when BCM Monitor is started or when the date changes while BCM Monitor is running. time Message output time This is only displayed when the output destination is SYSTSPRT. date New date For example, Thursday, 21 Jan 2010 is displayed.
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Copy group monitoring status (ACTIVE or INACTIVE) cgsastat Copy group startup status to be checked when BCM Monitor starts cgsaact Startup action executed if the copy pair status for starting BCM Monitor is different from the specified startup status cgsaopt Option information of the CGSTARTUPSTATUS parameter status action e
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions To continue using this product after the expiry date, you need a permanent license. If function is Basic: A permanent license for Business Continuity Manager Basic is required. If function is Cnt Ac-S Z Sync Extended CTG: A permanent license for Business Continuity Manager Extended CT Group is required.
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKA007E TSO TIMEOUT() value not valid The value specified in the TIMEOUT parameter is invalid. YKA008E TSO TIMEOUT() parameter cannot be specified for this operation If GET or CLOSE is specified in the OP parameter, you cannot specify the TIMEOUT parameter.
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions created for the volume that was successfully detected. 44: The processing was cancelled due to an error. The copy group definition file was not created. 48: The command ended due to an invalid parameter. YKB002I TSO No copy pair was discovered. No copy pair was detected within the specified range.
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKB200W TSO No information was acquired for DEVN=device-number No copy pair information was acquired from the volume to which the device number was assigned. There might not be a volume for the specified device number. If the volume exists for the specified device number, check the channel settings.
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions The command control address number of the detected undefined volume YKB204W TSO A dynamic configuration change was detected. DEVN=device-number A dynamic change was detected in an I/O configuration definition while the YKP2B command was executing with CHECK specified for the HS parameter.
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKC0x) (continued) Message ID Message Text Explanation and Recommended Actions Stem name assigned to the MSG parameter YKC002E MSG SC=48 RC=48 Results STEM(stem) does not include trailing "." The last character of the STEM parameter is not a period.
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKC0x) (continued) Message ID Message Text Explanation and Recommended Actions Check the disk configuration definition file after the scan is complete. If the volume serial number is different from the one in the actual configuration, re-execute the scan. YKC099I TSO YKSCAN command return The YKSCAN command terminated with the return code nnnn and code=nnnn, reason code=rrrr the reason code rrrr.
Table 4 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKD0x) (continued) Message ID Message Text Explanation and Recommended Actions YKD058E MSG SC=36 RC=48 Some pairs in this group do not support Hitachi TrueCopy™ Asynchronous for Mainframe (TCA) services. One or more devices in the HP XP 256 Disk Array storage system do not support TCA copy groups.
Table 5 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKE0x) (continued) Message ID Message Text Explanation and Recommended Actions Stem name assigned to the MSG parameter YKE002E MSG SC=48 RC=48 TIMEOUT() value invalid The value assigned to the TIMEOUT parameter is invalid. YKE003E MSG SC=48 RC=48 GOTO value is invalid. The value assigned to the GOTO parameter is invalid.
Table 6 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKF0x) (continued) Message ID Message Text Explanation and Recommended Actions YKF001E MSG SC=48 RC=48 No results STEM() supplied Nothing is assigned to the STEM parameter. YKF002E MSG SC=48 RC=48 Copy Group STEM(stem) The last character of the STEM parameter is not a period. does not include trailing ".
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions YKG003E TSO RC=52 Unable to update MSG(stem) An attempt to assign a value to a Message structure variable failed. in Caller's environment. The resulting value is displayed in result. This error can be caused YKVSET result = result by an invalid value being specified for the MSG parameter.
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions rec# Number of the line in the file identified by file where the error was detected YKG052W MSG SC=4 RC=4 (file:rec#) Expecting new element. Found "string". XML input analysis detected a syntax error on the line with the line number identified by rec# in the file identified by file.
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKG075W MSG SC=4 RC=4 (file:rec#) Unrecognized Encoding attribute value: value The system does not recognize the encoding attribute value of the XML element that exists on the line with the
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions v.r.m API level For details about this value, see the information about the XML document type definitions in the HP P9000 for Business Continuity Manager Software Reference Guide.
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions YKG092E MSG SC=40 RC=40 (file) File Read error: dsstate. An attempt to read the XML file identified by file failed. dsstate Status of the input XML file file Name of the XML file where the error was detected YKG099I MSG TSO YKGETHDA command return code=max-value,reason code=reason-code.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions file Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKG251E MSG SC=36 RC=36 (file:rec#) name attribute missing. The required XML attribute name is missing.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG271E MSG SC=36 RC=36 (file:rec#) The element name is required, but no element was found. The required XML element name is missing. Correct the specification on the line with the line number identified by rec# in the file identified by file.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions Number of the line in the file identified by file where the error was detected YKG277E MSG SC=36 RC=36 (file:rec#) name element missing. The XML element name is missing. Correct the specification on the line with the line number identified by rec# in the file identified by file.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG298E MSG YKGETHDA encountered an An unexpected error has occurred. TSO SC=44 RC=44 unexpected error. This error might have occurred with another error. (detailed-info) If another error message was output at the same time as this one, follow the instructions in that message to fix the corresponding problem.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH002I TSO No copy pair was discovered. No copy pairs were detected within the specified range. YKH100E TSO Check the operating range and status of the copy pair that you want to acquire, and execute the YKH2B command again. If the copy pair status is SIMPLEX, the YKH2B command will not detect the copy pair.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH201W TSO No I/O paths are available No copy pair information was acquired from the volume to which for the specified devices. the device number Devn was assigned because no I/O paths are DEVN=Devn available.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH205W TSO This copygroup does not Cnt Ac-S Z with the HyperSwap attribute cannot be used in this support LinkageOption=HS. storage system because 2DC configuration with HyperSwap and SUPFNC=SUPFnc Cnt Ac-J Z is not supported. Use a device# in which 2DC configuration with HyperSwap and Cnt Ac-J Z can be used.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions If no additional information is available, a space is displayed. The error messages message-text, message-value, and message-severity are displayed in the TSO/E terminal. Depending on the length of the error messages, they might extend over several lines. YKJ099I TSO RC=0 cmd command completed.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions DD name of the CSV file where the error was detected YKJ152E TSO RC=40 Failed to operate csv file: dd-name: dsstate The CSV file operation will stop because an error occurred when using the CSV file. See the information output in the message to review the environment, and then update the CSV file again.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ202I TSO RC=4 No copy pair is defined in specified Pair information CSV file. No copy pair is defined in the pair information CSV file. No data was written in the copy group definition file. YKJ203E TSO RC=32 The number of items specified on one line of the pair information CSV file is incorrect.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions rec# Number of the line in the file identified by dd-name where the error was detected YKJ208W TSO RC=8 Inconsistencies exist among the values used to specify the secondary volume: dd-name: rec# The S-VOL specified with the device number differs from the S-VOL specified with the storage system serial number, CU number, an
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions and a C/T group ID is used The serial numbers of the primary site storage systems are the same; for multiple CAJ Copy the serial numbers of the secondary site storage systems are Groups: dd-name: rec# different; and copy pairs with an equal C/T group ID exist.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions DD name of the CSV file where the error was detected rec# Number of the line in the file identified by dd-name where the error was detected YKJ251E TSO RC=32 The value value of name in The format of the value assigned to name in the EXCTG information EXCTG information CSV file CSV file is invalid.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions DD name of the CSV file where the error was detected YKJ256E TSO RC=32 This entry does not have any The pair information CSV file includes no entry (line) corresponding corresponding Copy Group to the entry (line) specified in the EXCTG information CSV file.
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions service=service-name, code=code1, code2. Name of the OS service that encountered an error code1 Return code of the OS service that encountered an error code2 Reason code of the OS service that encountered an error If no reason code is returned for an OS service, 0 is output.
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL007E MSG SC=48 RC=48 Unable to execute without valid GROUP parameter. Specify a valid GROUP parameter. YKL050W MSG SC=4 RC=4 (file:rec#) Unrecognized element encountered: name Correct the specification on the line with the line number identified by rec# in the file identified by file.
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions Number of the line in the file identified by file where the error was detected YKL074E MSG SC=36 RC=36 (file:rec#) Invalid "&" character discovered in quoted string. string An invalid entity reference was found on the line with the line number identified by rec# in the file identified by file.
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP P9000 for Business Continuity Manager Software Reference Guide.
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions pair-index See the pair index description in the explanation of the YKE003E message. YKL083W MSG SC=12 RC=12 (pair-index) Unable to resolve volume serial number. The YKLOAD program failed to resolve the volume serial number of the P-VOL in the specified CopyPair.
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text YKL091E MSG File Deallocation Failed: SC=40 RC=40 (file) dsstate. Explanation and Recommended Actions An attempt to deallocate the XML file identified by file failed. dsstate Status of the input XML file file Name of the XML file where the error was detected YKL092E MSG File Read error: dsstate.
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions XML attribute name file Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKL250E MSG SC=36 RC=36 (file:rec#) The value value of the attribute name is an invalid format. The value value of the XML attribute name is in an invalid format.
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL254E MSG SC=36 RC=36 (file:rec#) The value value of attribute name is not match with filename. The value value of the XML attribute name does not match the name in the file name. Correct the specification on the line with the line number identified by rec# in the file identified by file, or correct the file name.
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL275W MSG SC=4 RC=4 (file:rec#) Extra ETag is specified: Etag-name An extra Etag-name is specified. Correct the specification on the line with the line number identified by rec# in the file identified by file.
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKL290E MSG SC=44 RC=44 (result) YKVGET program failure for: vn An attempt to acquire the variable vn failed with the result value identified by result.
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL295E MSG SC=44 RC=44 (file:rec#) The element stack was overflowed. The internal routine encountered a shortage of work space. Contact technical support for assistance.
Table 11 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM001E MSG SC=48 RC=48 No results STEM() supplied Nothing is assigned to the STEM parameter. YKM002E MSG SC=48 RC=48 Copy Group STEM(stem) does The last character of the STEM parameter is not a period. not include trailing ".
Table 11 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM017I LOG message-text The console message message-text was output when issuing the command. YKM018E ISPF A Consistency Group ID (C/T To define a TCA copy group, a C/T group ID is required. ID) is required for CA Async Copy Group definition. YKM020E ISPF Please supply the required information.
Table 11 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM037E ISPF Changing a local Device Address Domain ID is not allowed. Changing a local device address domain ID is not allowed. YKM038E ISPF Specified DEVN is not found. The device number you specified was not found. YKM039E ISPF Specified device is not command device because APID is not available.
Table 11 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions Correct the value and then re-execute the command. name REXX variable name attribute-value REXX variable value YKM056E MSG SC=36 RC=48 NOCOPY option invalid for BC Z Copy Group The YKMAKE command with the NOCOPY parameter specified was executed on an BC Z copy group. This parameter is invalid on BC Z copy groups.
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions YKM504E ISPF The number of connections of inter-DKC paths of the same PathID exceeds the maximum number of connections that is allowed within the same storage system. The number of connections of inter-DKC paths of the same PathID exceeded the maximum that is allowed within the same storage system.
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions YKM518E ISPF Port errport exceeds the limit that is allowed in this composition. The number of ports exceeds the maximum number for this composition.
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) Message ID Message Text Explanation and Recommended Actions YKM700E ISPF Enter one of the listed values. Enter one of the listed values. YKM701E ISPF Enter required field at the cursor position. Enter the required information at the cursor position. YKM702E ISPF The length of the data must be The length of the input data must be crtlen. = crtlen.
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions value-length Input length YKM725E ISPF Enter the number (hex. characters: 0-9, A-F, a-f). Enter the hexadecimal characters (0-9, A-F, a-f). YKM726E ISPF Enter the number (numerical characters: 0-9). Enter a numeric value (0-9). YKM727E ISPF Range specification is not supported for the field.
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions the first character being an alphabetic character (A-Z, a-z). The length of Copy Group ID must be 1-40. YKM757E ISPF The 4-digit year (YYYY) or 2-digit month (MM) or 2-digit day (DD) was not numeric. Valid year values are 0000-9999, valid month values are 01-12, and valid day values are 01-31.
Table 14 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM9x) (continued) Message ID Message Text Explanation and Recommended Actions Execute the YKSTART command in an ISPF environment. After that, you can execute whichever Business Continuity Manager commands you need to. YKM902E TSO Load module is not found. The Business Continuity Manager load module was not found. The Business Continuity Manager dataset might not be concatenated to the LNKLST.
Table 15 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKN0x) (continued) Message ID Message Text Explanation and Recommended Actions YKN001E MSG SC=48 RC=48 No results STEM() supplied Nothing is assigned to the STEM parameter. YKN002E MSG SC=48 RC=48 Copy Group STEM(stem) does The last character of the STEM parameter is not a period. not include trailing ".
Table 16 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKP0x) (continued) Message ID Message Text Explanation and Recommended Actions YKP002E TSO RC=48 Messages MSG(stem) does not The last character of the MSG parameter is not a period. include trailing ".
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions Stem name assigned to the STEM parameter YKQ002E MSG SC=48 DEVN() value invalid YKQ002E TSO RC=48 Messages MSG(stem) does not include trailing "." The value assigned to the DEVN parameter is invalid. The last character of the MSG parameter is not a period.
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions Check that the copy group indicates the correct volumes and is not being used for other purposes. device# Device number If the device cannot be identified, **** is displayed. SN Storage system serial number If the device cannot be identified, ************ is displayed.
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions Check that the copy group indicates the correct volumes and is not being used for other purposes, make the P-VOL online, and then re-execute the YKQUERY command. device# Device number If the device cannot be identified, **** is displayed.
Table 18 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKR0x) (continued) Message ID Message Text Explanation and Recommended Actions YKR002E MSG SC=48 DEVN() value invalid The value assigned to the DEVN parameter is invalid. YKR002E TSO RC=48 Messages MSG(stem) does not The last character of the MSG parameter is not a period. include trailing ".
Table 19 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS0x) (continued) Message ID Message Text Explanation and Recommended Actions indicates the most likely cause of the error indicated in the previous YKS003E message. YKS003E TSO RC=52 Unable to update MSG(stem) in An attempt to assign a value to a variable of the Message Caller's environment. YKVSET structure failed with the result value indicated by result.
Table 19 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS0x) (continued) Message ID Message Text Explanation and Recommended Actions • BLKSIZE = XX.BLKSIZE must be YY The file is unavailable because the BLKSIZE attribute value is abnormal. Therefore, delete the current configuration file, and then create a new configuration file that has correct file attributes. • ALLOCATION FAILED Creation of a configuration file failed.
Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS2x) (continued) Message ID Message Text Explanation and Recommended Actions YKS250E MSG SC=36 RC=36 The value value of the variable name is an invalid format. The value value of the variable identified by name is invalid. YKS260E MSG SC=44 RC=44 Too long record:record. An attempt to output record to a dataset failed because record was too long.
Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS2x) (continued) Message ID Message Text Explanation and Recommended Actions YKS290E MSG SC=44 RC=44 (result) YKVGET program failure for:vn An attempt to acquire the variable vn failed with the result value identified by result. This error can be caused by the YKSTORE REXX subroutine's compiled REXX module being directly executed.
Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT0x) (continued) Message ID Message Text Explanation and Recommended Actions YKT007W CON RC=16 Couldn't delete SVC entry SVC number deletion failed in the SVCUPDTE macro. Contact technical support for assistance. YKT008E CON RC=20 System task started without START from TSO. The YKALCSVC command was executed in the TSO/E environment.
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT2x) (continued) Message ID Message Text Explanation and Recommended Actions YKT213E CON RC=4 Couldn't take Name/Token An error occurred during acquisition of Name/Token. The program stops processing. Contact technical support for assistance. YKT219E CON RC=16 Processing ended abnormally Processing terminated abnormally before completion. The program stops processing.
Table 23 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT4x) Message ID Message Text Explanation and Recommended Actions YKT400I CON Business Continuity Manager environment variables (version) This message displays the Business Continuity Manager environment variables. version Version of Business Continuity Manager YKT401I CON variable : value This message displays the Business Continuity Manager environment variables.
Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKU0x) Message ID Message Text Explanation and Recommended Actions YKU000T TSO RC=48 Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKU099I message that will appear after this message. For reason codes, see IKJPARS in the TSO/E Programming Services. YKU001E TSO RC=48 No message MSG() supplied Nothing is assigned to the MSG parameter.
Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKU0x) (continued) Message ID Message Text Explanation and Recommended Actions YKU010E TSO RC=40 REXX failure return code=nnnn starting with variable name Access to the REXX variable identified by name failed. For details about the return code, see IKJCT441 in the TSO/E Programming Services.
Table 25 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKV0x) Message ID Message Text Explanation and Recommended Actions YKV000T TSO RC=48 Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKV099I message that will appear after this message. For reason codes, see IKJPARS in the TSO/E Programming Services. YKV001E TSO RC=48 No message MSG() supplied Nothing is assigned to the MSG parameter.
Table 25 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKV0x) (continued) Message ID Message Text Explanation and Recommended Actions Maximum among the severity codes returned during command execution Table 26 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKW0x) Message ID Message Text Explanation and Recommended Actions YKW001W TSO Timeout limit has expired without The specified copy group copy-grou
Table 26 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKW0x) (continued) Message ID Message Text Explanation and Recommended Actions nnnn Return code of the YKCONMSG command For details, see the description for the YKCONMSG command in the HP P9000 for Business Continuity Manager Software Reference Guide. YKW009W TSO Terminated due to Operator attention. An interrupt occurred during execution of the YKWATCH command.
Table 27 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX0x) (continued) Message ID Message Text Explanation and Recommended Actions For details about the return code, see IKJCT441 in the TSO/E Programming Services. nnnn Error code returned upon REXX access YKX065W MSG SC=4 RC=0 Storage system serial-number Command Device Definition Failed. The command device definition for the storage system identified by serial-number failed.
Table 28 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX1x) (continued) Message ID Message Text Explanation and Recommended Actions YKX102E TSO RC=48 Messages MSG(stem) does not include trailing "." The last character of the MSG parameter is not a period. stem Stem name assigned to the MSG parameter YKX103E MSG SC=48 Parameter combination is invalid The specified parameter combination is invalid.
Table 29 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX2x) (continued) Message ID Message Text Explanation and Recommended Actions YKX201E MSG SC=48 No device# DEVN() supplied Nothing is assigned to the DEVN parameter. YKX201E TSO RC=48 No message MSG() supplied Nothing is assigned to the MSG parameter. YKX201E MSG SC=48 No model SMODEL() supplied Nothing is assigned to the SMODEL parameter.
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) Message ID Message Text Explanation and Recommended Actions YKY001I CON AGENT STARTED (vv-rr[-zz]) The Business Continuity Manager agent has started.
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) (continued) Message ID Message Text Explanation and Recommended Actions YKY016I CON TASK(task-ID) ABENDED,CODE= A task terminated abnormally during the agent start up. The Business Continuity Manager agent will be completion-code terminated.
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) Message ID Message Text Explanation and Recommended Actions YKY100I CON MODIFY COMMAND ACCEPTED The MODIFY command was accepted. YKY101I CON STOP COMMAND ACCEPTED The STOP command was accepted. YKY102I CON INVALID error-type: text After an entry of the MODIFY command, an error was detected in the command or operand shown as text. Check, and, if necessary, revise the command.
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) (continued) Message ID Message Text Explanation and Recommended Actions port-number • When LOCAL is displayed in host-type: The port number of the local host • When REMOTE is displayed in host-type: The port number of the remote host IP-address • When LOCAL is displayed in host-type: The IP address of the local host • When REMOTE is displayed in host-type: The IP address of the remote host YKY
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions Number used to identify the processing task that output the message YKY301I SYS hh:mm:ss task-ID,TCP CONNECTION ENDED NORMALLY The TCP connection was released successfully.
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions IP-address IP address of the remote host remote-port-number Port number of the remote host local-port-number Port number of the local host YKY315I CON task-ID,COMMUNICATION ERROR,@API[,request-name [,RC=response-code]] [,EC=event-code] [,SRC= local-IP-address: local-port-number] [,DST= connection-target-IPaddress:connecti
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions Port number of the connection target host YKY321I CON task-ID,COMMUNICATION TIMED There is no response within the specified response OUT wait time. The connection will be released. Check the cause of the response timeout.
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions Indicates the result • SUCCESS: The update succeeded. • FAILURE: The update failed. YKY501E XML Disk configuration definition error-type error. file An error occurred in the disk configuration definition file. See the error-type, and then remove the error. After that, retry the operation from Replication Manager.
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions • DELETE: A deletion error • RENAME: A renaming error file Name of the temporary file in which an error occurred YKY507E XML Routelist configuration file error error-type. file An error occurred in the route list definition file. See the error-type, and then remove the error.
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions YKY605I CON IRXINIT MODULE ERROR,CODE=return-code, R0=abnormal-termination-code- The IRXINIT routine returned an error with the return code shown as return-code. The Business Continuity Manager agent will terminate the processing. and-reason-code-for-abnormal- Check the return code.
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions abnormal termination set in the two leading bytes of R0. If the reason code for abnormal termination is larger than two bytes, IRXTERM returns only the two trailing bytes of the reason code for abnormal termination. For details about the abnormal termination code and reason code, see the MVS System Codes.
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions contents-of-register-2 contents-of-register-3 yy-mm-dd GR 04-07 contents-of-register-4 contents-of-register-5 contents-of-register-6 contents-of-register-7 GR 08-11 contents-of-register-8 contents-of-register-9 contents-of-register-10 contents-of-register-11 Date the task terminated abnormally hh:mm:nn Time the task ter
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions Check, and, if necessary, revise the request coding. YKY704E XML End of request was detected in the comment. The end of the XML request was detected in the comment. Check, and, if necessary, revise the comment. YKY705E XML End of request was detected in an element.
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions YKY717E XML A required element is missing from the request. 'element' A required element is missing in the request. Check, and, if necessary, revise the element specification in the request. element Name of the missing element YKY718E XML A required parameter is missing A required parameter is missing in the element.
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions • version: A version error Make sure that the definition information version is correct. • YKP2A: A definition-creation program error The requested operation cannot be performed because the configuration file of the copy group cgname was created by the Mainframe Agent YKP2A command.
Table 35 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ0x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ002E MSG SC=48 parameter-name() does not include The last character of the string assigned to the trailing "." parameter identified by parameter-name is not a period. YKZ003E MSG SC=48 parameter-name() value invalid The value assigned to the parameter identified by parameter-name is invalid.
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions Expand the job execution area, and then re-execute the command. nnn (decimal number) Return code from the GETMAIN macro mmm (decimal number) Area size area (string) HIGH must be equal to or greater than 16 MB; LOW must be less than 16 MB.
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ203E TSO RC=40# A REXX read error occurred.
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions If the error still exists after the above action has been taken, contact the service representative.
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ207E MSG TSO CON SC=52 RC=44# A Core process error occurred. (detail=message-text, cmd=xxx, pos=yyy) The command cannot be executed because a Core processing error occurred.
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions Maintenance information # If this message is output when the log and trace are obtained, the RC is 0. YKZ208I TSO CON PRT RC=0 The Core processing ( process ) started. (DATE=yyyy/mm/dd, TIME=hh:mm:ss.th, TOD=ttt, cmd=xxx, pos=yyy) Core processing is starting.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) Message ID Message Text Explanation and Recommended Actions YKZ210E MSG TSO CON SC=40 RC=44# A NAME/TOKEN read error occurred. (return code=nnn, name= name, cmd=xxx, pos=yyy) The command cannot be executed because a NAME/TOKEN read error occurred. Check that the YKLOAD command terminated normally.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text YKZ217E MSG CON PRT A Logger error occurred. (return SC=0 RC=0 code=nnn, reason code=mmm, name=name, cmd=xxx, pos=yyy) Explanation and Recommended Actions A system logger service error occurred.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions REXX variable value # If this message is output while the YKLOAD command is being executed, the RC is 44. YKZ220T MSG SC=36 RC=36# Group ID value null or invalid. The C/T group ID of the copy group structure is NULL or invalid. Correct the configuration file, and then re-execute the YKLOAD command.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions See the pair index description in the explanation of the YKE003E message. # If this message is output while the YKLOAD command is being executed, the RC is 44. YKZ224E MSG SC=8 RC=36# (pair-index) Primary device does not support TCA TCA cannot be used on a storage system with a P-VOL.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Check that the value is specified according to the following rules: • The command control address must consist of 2 digits. • The control unit number must consist of 2 digits. • The SSID must consist of 4 digits. • The storage system serial number must consist of 5 digits.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions See the pair index description in the explanation of the YKE003E message. YKZ231E MSG SC=44 RC=44 Necessary Routelist or DEVN information is not found. The route list or device number information is missing although it is required for processing to continue.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Correct the contents of the configuration file. name REXX variable name # If this message is output while the YKLOAD command is being executed, the RC is 44. YKZ238E MSG SC=36 RC=44 ATTIME SUSPEND remains in place. Suspension initiated by YKSUSPND ATTIME is still Pair operation process is canceled. in effect.
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ246E MSG SC=48 RC=48 This operation (operation) does not support remote command. This operation is not supported when a remote function is in use. operation Operation name YKZ247E MSG SC=44 RC=44 STEM(stem) information for Core Processing is not found. Information on the specified stem name is missing.
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ251E MSG SC=32 RC=32 (pair-index) DASD device device-number-1(device-number-2) management error, message-text.
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions device-number-1 (string) The device that issued I/O device-number-2 (string) The device to be manipulated message-text (string) Message text code1 (Hexadecimal number) Subcommand code code2 (Hexadecimal number) Error code For details about the error codes, see “Storage System Sense Byte Information” (page 163).
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions CSW information code3 (Hexadecimal number) Subcommand code code4 (Hexadecimal number) Completion code code5 (Hexadecimal number) Detailed code xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions code4 (Hexadecimal number) Completion code code5 (Hexadecimal number) Detailed code xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ257E MSG SC=32 RC=32 (pair-index) DASD device device-number-1(device-number-2) management error.
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ258E MSG SC=8 RC=8 DASD device device-number-1(device-number-2) management error. (Message type: code1 Reason code: code2 Error code: code3 code4, cmd=xxx, pos=yyy) Business Continuity Manager failed to complete the requested processing. Business Continuity Manager might not support this device.
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions YKLOGnn YKLOG01 or YKLOG02 xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ262E MSG CON SC=0 RC=0 A YKLOGnn open error occurred.
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions Return code from the CLOSE macro xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions KKK If DSORG is abnormal: DSORG If RECFM is abnormal: RECFM If LRECL is abnormal: LRECL If BLKSIZE is abnormal: BLKSIZE AAA File attribute that encountered an error (* is displayed when the file attribute is undefined or immediately after dataset allocation) BBB Valid file attribute xxx (decimal number) Command code of the
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions Items that do not match COPYTYPE: copy type GROUPID: consistency group ID, or Open/MF Consistency attribute PAIR: copy pair configuration device# Device number If the device cannot be identified, **** is displayed. SN Storage system serial number If the device cannot be identified, ************ is displayed.
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ274E MSG SC=36 RC=36 (index1, index2, index3) Duplicate ports exist in REVERSE. In the logical path definition for REVERSE index1, the index2 and index3 port numbers are duplicated. Delete one of the definitions or make sure that the duplicated port numbers are correct, and then re-execute the command.
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions performed after the storage system microcode was replaced, perform another scan. value IFType value of the remote storage system YKZ280W MSG SC=0 RC=0 Secondary volume's IFType is larger The IFType of a storage system using the Remote than Remote control's IFType value.
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions #1 If this message is output while the YKLOAD command is being executed, the RC is 44. #2 The Cnt Ac-J Z is used in a storage system where the first two digits of the IFType are X'11' or higher. YKZ283T MSG SC=36 RC=36# subCTGroupID value null or invalid.
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) Message ID Message Text Explanation and Recommended Actions YKZ290E MSG SC=48 RC=48 FROMCU() exceeds number of CU that storage systems supported. The FROMCU has exceeded the maximum number of CUs that are supported by storage systems. Specify the maximum supported number of CUs or less. YKZ291I CON SC=0 RC=0 The log dataset is full. (DSN=ddd, cp=xxx:yyy) The log dataset is full.
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions The return code of the ASASYMBM macro YKZ295E MSG SC=36 RC=36 The version of this configuration file is not supported. The version of this configuration file is not supported. YKZ296E MSG SC=44 RC=44 A JNLG is not registered in EXCTG.
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions JNLG (string) The journal type not being registered (the journal type of the definition, rather than of the storage system) R-JNL: Journal of the secondary site M-JNL: Journal of the primary site jj (hexadecimal number) The journal group number (00-FF) specified by the C/T group ID or sub C/T group ID m (decimal number) Mi
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions cccc (hexadecimal number) Arbitration command device number (0000-3FFF) FFFF is displayed for the supervisor DKC. nnnn (hexadecimal number) Error code For details about the error codes, see “Storage System Sense Byte Information” (page 163).
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions The journal group number registered to the storage system (00-FF) m (decimal number) The mirror ID registered to the storage system (0-3) e (decimal number) The EXCTG ID registered to the storage system (0-3) ssssssssssss (decimal number) The serial number registered to the storage system cccc (hexadecimal number) The arbi
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions Issued CLI command name and its parameters A maximum of 109 characters can be output. If 109 is exceeded, the remainder are discarded. YKZ311I CON hh:mm:ss command RC=rc This log data indicates the result of a CLI command execution.
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ332E TSO RC=64 command detected the system abend An abnormal system termination was detected during during rexx-service processing. the REXX service processing. (code=sss, reason=rrrr). command Issued CLI command name. rexx-service Name of the REXX service where the abnormal system termination was detected.
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions For details on error codes, see “Storage System Sense Byte Information” (page 163)n. If the error code is not listed in the manual, contact maintenance personnel.
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions the YKQUERY command to determine the cause of the problem and rectify the error.
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions #1 If this message is output while the YKLOAD command is being executed, the RC is 44. #2 EXCTG is used in a storage system where the first two digits of the IFType are X'13' or higher. YKZ406E MSG SC=36 RC=36#1 Secondary device IFType does not support EXCTG.
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions 3: The suspend processing ended abnormally. uu (decimal number) Status of Continuous Access Journal(0 or 1) 0: All Continuous Access Journal copy pairs were in the DUPLEX status during the suspension. 1: During the suspension, there was a Continuous Access Journal copy pair whose status was not DUPLEX.
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions 4: Suspension was performed because the system detected a no-update journal. ss (decimal number) Status of BC Z (0-3) 0: The suspend processing has not started. 1: The suspend processing is in progress. 2: The suspend processing ended successfully. 3: The suspend processing ended abnormally.
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions C/T group ID for BC Z (00-7F) jj (hexadecimal number) Journal group number specified for the sub C/T group ID for the Cnt Ac-J Z that links with BC Z. gg (hexadecimal number) Generation ID (00-FF) ATTIME-suspend-time (GMT) ATTIME suspend time: YYYYMMDD-HH:MM:SS.NNNNNN YYYY: Year MM: Month DD: Day HH: Hour MM: Minute SS.
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions SUPFnc (hexadecimal number) Value for the version of the storage system support function used in the copy group (minimum) # The CAJ ATTIME suspend function can be used in a storage system where the version of the storage system support function are X'14' or higher.
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions • LinkageOption=HS: 2DC configuration with HyperSwap and Cnt Ac-J Z • AttimeSplitMode=QUICK: Quick suspend mode for the CAJ ATTIME suspend function #1 If this message is output while the YKLOAD command is being executed, the RC is 44.
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions Device number defined in the disk configuration definition file sn Serial number of the storage system on which the device indicated by devn actually exists YKZ416E MSG SC=36 RC=36#1 Copygroup SUPFnc does not support CA Map (DIF UNIT).
SIMPLEX MATCHING% PENDING REVERSED% DUPLEX ATTIME SUSPEND -STATUS OTHER : : : : : : : : : The results of REPORT(SUMMARY)are displayed.
: Copy pair matching percentage : Consistency group ID or master journal group ID : Restore journal group ID : Consistency delta value for each consistency group : Consistency time for each consistency group YK8314I PRT REPORT COPY C/T ID RPO: GROUP : SUB PRI- SECC/T SN SN C/T C/T DELTA TIME The results of REPORT(RPO)are displayed.
: Data transfer rate (Kbps) between the main control unit and the remote control unit : Offloading timer : Remote control unit ready timer : Copy pending timer YK8318I PRT REPORT STATS: COPY GROUP : PREFIX : DAD-ID : TYPE : MJNL RJNL C/T SUB PRI- SECID C/T SN SN PRI %S SEC %S - PRI GB - - SEC GB TRANS JNL-VOL JNL-VOL -- JNL-VOL -- JNL-VOL KBYTES/S MET DAT MET DAT DAT DAT The results of REPORT(STATS) for the CAJ copy group are display
: Stop point : Sleep point YK8413I PRT COPY GROUP DEFINITIONS: ID : PREFIX : DAD-ID : ROUTE LIST : MONITOR STATUS : STARTUP STATUS : ,, [ WHEN STATUS DO ACTION '' The values specified in the YKMONCG file are displayed. This message appears a number of times, equal to the number of copy groups specified.
Table 46 User Completion Codes (continued) Completion Code Explanation The user who attempted to execute the command has been granted only the view permission for the STGADMIN.YKA.BCM.YKQUERY profile. Therefore, the user cannot execute CLI commands to operate copy pairs, paths, and command devices. If the reason code is other than the above: The information returned from the RACROUTE REQUEST=AUTH macro is displayed. For details, see the Security Server RACROUTE Macro Reference.
2 Storage System Sense Byte Information This chapter describes storage system sense byte information (error codes) contained in messages that are output by Business Continuity Manager. Details of Error Codes This section lists the details on the storage system sense byte information (error codes) that are output to messages. If an error code not listed in this table is output, contact service representative.
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z BC Z copy pair is a part of a delta resync pair. 2089 A BC Z copy pair cannot be resynchronized (QuickRestore) because the P-VOL of the specified BC Z copy pair is being quick formatted. Output Not output 208A A BC Z copy pair cannot be resynchronized (QuickRestore) because the S-VOL of the specified BC Z copy pair is being quick formatted.
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Code Error Details Type of Error 20BD A copy pair could not be created because the P-VOL of the specified BC Z copy pair is an emulation type (3390-V) that is not supported. Output Not output 20BE A copy pair could not be created because the S-VOL of the specified BC Z copy pair is an emulation type (3390-V) that is not supported.
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Code Error Details Type of Error 22F7 A BC Z copy pair cannot be made Output Not output because the specified S-VOL is either a P-VOL or S-VOL for FlashCopy. 22F9 A BC Z copy pair cannot be resynchronized (by either ReverseResync or QuickRestore) because the volume is of a common volume configuration consisting of a P-VOL of BC Z and a P-VOL of FlashCopy.
Table 48 Details of Error Codes 23xx (continued) Error Code Error Details Type of Error 2312 The command could not be executed Output Not output because the S-VOL of a BC Z copy pair is online. 2313 An BC Z copy pair cannot be suspended because the copy pair is in the Split status. Output Not output 2314 A BC Z copy pair cannot be made because the copy pair is in the Split status. Output Not output 231B A BC Z copy pair status cannot be Output Not output changed.
Table 48 Details of Error Codes 23xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z specified to be the P-VOL is already the S-VOL. 233A A BC Z copy pair cannot be Output Not output resynchronized because the copy pair is in the SIMPLEX status. 233F A BC Z copy pair cannot be Output Not output resynchronized with Reverse specified because a Cnt Ac-S Z or TCA copy pair is not in the suspend status.
Table 48 Details of Error Codes 23xx (continued) Error Code Error Details Type of Error 2358 A BC Z copy pair status cannot be Output Not output changed. The reason might be one of the following: BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others • The status of another copy pair that shares the P-VOL or S-VOL is TRANS. • There is a FlashCopy pair that shares the P-VOL or S-VOL.
Table 48 Details of Error Codes 23xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z specified to be the S-VOL is a command device. 2390 A BC Z copy pair cannot be made because the volume specified to be the P-VOL is being quick formatted.
Table 48 Details of Error Codes 23xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others suspend function cannot be executed. • The ATTIME suspend function cannot be executed because the P-VOL is a Non Gen'ed volume. 23BB A BC Z copy pair cannot be made because the LDEV security is set for the specified S-VOL. Output Not output 23EF A BC Z copy pair cannot be deleted Output Not output because the specified BC Z copy pair is in SUSPVS status.
Table 49 Details of Error Codes 36xx Error Code Error Details 3613 Registration to EXCTG has failed because the specified arbitration command device is not an arbitration command device. 3614 Registration to EXCTG has failed.
Table 49 Details of Error Codes 36xx (continued) Error Code Error Details 3685 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Registration to EXCTG has failed Not output because the specified storage system model name is invalid. Output Not output 3686 Registration to EXCTG has failed because the journal group to be registered is already registered to another EXCTG.
Table 50 Details of Error Codes 37xx (continued) Error Code Error Details 3707 A delta resync pair cannot be executed. The reason might be one of the following: Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output 3709 The delta resync command cannot be Not output executed because there are no Cnt Ac-J Z copy pairs with a mirror ID other than the one specified for the delta resync pair in the specified R-JNL group.
Table 50 Details of Error Codes 37xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others to be the P-VOL is a system residence volume. 3728 A Cnt Ac-J Z copy pair cannot be Not output made because an unsupported volume was specified when making a copy pair between different models.
Table 51 Details of Error Codes 46xx (continued) Error Code Error Details 4603 A Cnt Ac-J Z copy pair cannot be dissolved. Possible reasons include one or both of the following: Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output 4606 The Cnt Ac-J Z copy pair status could Not output not be acquired because the specified CU number is unsupported.
Table 51 Details of Error Codes 46xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others system and serial number of the secondary storage system do not match the serial number of the local storage system. 4617 A Cnt Ac-J Z copy pair cannot be Not output suspended, resynchronized or dissolved because the specified volume is not a Cnt Ac-J Z copy pair.
Table 51 Details of Error Codes 46xx (continued) Error Code Error Details Type of Error 463C Due to either of the following Not output reasons, CAJ ATTIME suspensions cannot be scheduled in Quick mode: BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Output Not output • The storage system does not support the CAJ ATTIME suspend function in Quick mode. • The microcode of the storage system is currently being changed to one that supports the CAJ ATTIME suspend function in Quick mode.
Table 51 Details of Error Codes 46xx (continued) Error Code Error Details 4668 The CAJ ATTIME suspend time cannot be set because three generations of suspend time have already been set for the specified R-JNL group. 4669 466A Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output The CAJ ATTIME suspend time cannot be set because another suspend time has already been set for the C/T group of the specified BC Z copy pair.
Table 51 Details of Error Codes 46xx (continued) Error Code Error Details 467C The CAJ ATTIME suspend time cannot be set because a copy pair that is not in the Duplex status is included in the specified BC Z C/T group. 4681 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output A BC Z copy pair cannot be made, Not output resynchronized, or suspended because the CAJ ATTIME suspend time has been set for the specified BC Z C/T group.
Table 53 Details of Error Codes 4Axx Error Code Error Details Type of Error 4A08 The C/T group ID specified for the TCA C/T group option change is incorrect. Not output Output Not output 4A0B The C/T group ID specified for the Not output TCA C/T group option change is not registered. Output Not output 4A0C The C/T group timer type Not output (SYSTEM/LOCAL/NONE) for the TCA cannot be changed because there is a copy pair in this C/T group.
Table 53 Details of Error Codes 4Axx (continued) Error Code Error Details 4A8B The command could not be executed Not because the status of the Cnt Ac-S Z output or TCA copy pair is invalid. Output Not output 4A8C The command could not be executed Not because the status of the Cnt Ac-S Z output or TCA copy pair is being changed. Output Not output 4A8D The command could not be executed Not because the status of the Cnt Ac-S Z output or TCA copy pair is invalid.
Table 54 Details of Error Codes 4Bxx Error Code Error Details 4B02 A copy pair cannot be resynchronized because the copy pair is in a status that cannot be changed. The reason might be one of the following: Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z Not output Output Not output Not output CMD PATH Others • The copy pair cannot be resynchronized because the copy group definition contains a C/T group ID, but the actual copy group does not.
Table 54 Details of Error Codes 4Bxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z specified cannot be dissolved because the copy pair status does not allow the status to be changed. The reason might be one of the following: • The specified volume is not in a Cnt Ac-S Z copy group with a C/T group ID specified. • The copy pair is in the SIMPLEX status.
Table 54 Details of Error Codes 4Bxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z Not output Output TCA Cnt Ac-J Z CMD PATH Others specified. The reason might be one of the following: • The specified volume is not in a Cnt Ac-S Z copy group with a C/T group ID specified. • The specified volume is using the Open/MF Consistency Preservation Function. • The copy pair is in the SIMPLEX status.
Table 54 Details of Error Codes 4Bxx (continued) Error Code Error Details Type of Error 4BA9 A TCA copy pair cannot be made because the specified CTID is not registered in the storage system. 4BB1 No timestamp transfer mode Cnt Not Ac-S Z copy pair can be made output because the specified volume is not a Cnt Ac-S Z copy pair. Output Not output 4BB2 A timestamp transfer mode Cnt Ac-S Not Z copy pair cannot be made output because the specified volume is an XRC pair.
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others • The corresponding volume is online. • The corresponding volume is being used by another program product such as BC Z, Cnt Ac-S Z, TCA, Cnt Ac-J Z or FlashCopy. • The emulation type of the corresponding volume is 3390–V. 64FC A command device cannot be redefined because the APID that was already defined does not match the APID you attempted to define.
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Code Error Details Type of Error 69F3 A copy pair cannot be made. The Output reason might be one of the following: BC Z Cnt Ac-S Z TCA Cnt Ac-J Z Not output • The storage system serial number of the P-VOL is incorrect. • The SSID of the P-VOL is incorrect. • The CU number is not supported. • The storage system does not support the Open/MF Consistency Preservation Function.
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Code Error Details Type of Error 6A07 The command could not be executed because the corresponding volume is not the P-VOL of a TCA copy pair or it is a Non Gen'ed volume. Not output Output Not output 6A08 An ATTIME suspend time for TCA Not output cannot be set because there is a copy pair that is not in the DUPLEX status.
Table 56 Details of Error Codes 7Fxx – 8Cxx Error Code Error Details Type of Error 7F86 The command cannot be executed because no program product for copying is installed. Not output Output 7FD4 This command is not supported. Not output Output 8C12 A Cnt Ac-S Z or TCA copy pair status cannot be changed. Possible reasons include one or more of the following: Not output BC Z • The specified S-VOL is online.
Table 56 Details of Error Codes 7Fxx – 8Cxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others • A copy pair cannot be made because the same C/T group ID is set in both the MCU and RCU. • The specified C/T group ID is not registered. • Alternatively, a path cannot be defined and deleted because either the copy pair status or the parameter is invalid. (The possible reasons are documented by error codes C120 to C12F.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error 8D10 A copy pair cannot be made. The Output reason might be one of the following: BC Z Cnt Ac-S Z TCA Cnt Ac-J Z Not output CMD PATH Others Output Not output • An inter-CU logical path has not been set between the specified CUs. • The storage system serial number of the P-VOL is incorrect. • The SSID of the P-VOL is incorrect. • The CU number is not supported.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others For details, see error code 2310. • The charging limit of the program product was exceeded. • The copy pair is in the Pending status. • The copy pair is not in the Split status. • The specified C/T group ID is not registered. 8D17 The command could not be executed because the BC Z, Cnt Ac-S Z, or TCA program product is not installed.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others N N N N N Y For details, see error code 2310. • The P-VOL is online. • The charging limit of the program product was exceeded. • The copy pair is in the Pending status. • The copy pair is not in the Split status. • The specified C/T group ID is not registered. • The number of copy pairs in the specified C/T group ID exceeds the maximum number.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others include one or more of the following: • The status of the copy pair does not allow the status transition. For details, see error code 2310. • The copy pair is in the SIMPLEX status. • The copy pair is in the Split status. • The specified C/T group ID is not registered.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z Output Not output TCA Cnt Ac-J Z CMD PATH Others • The status is invalid. • The status of the copy pair is being changed. 8D2A A BC Z copy pair cannot be suspended. Possible reasons include one or more of the following: • The status of the copy pair does not allow the status transition. For details, see error code 2310. • The copy pair is in the SIMPLEX status.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others command device is a volume used in the open system. 8D43 The command could not be executed because the logical volume of the specified volume is blocked. Not output Output Not output 8D44 The command could not be executed because the specified volume has PIN data. Not output Output Not output 8D45 The command device cannot be defined.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z volume of the specified volume is blocked. 8D56 A BC Z copy pair cannot be Output dissolved. Possible reasons include one or more of the following: Not output • The status of the copy pair does not allow the status transition. For details, see error code 2310. • The copy pair is in the V-Split status. • The specified C/T group ID is not registered.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others • The S-VOL number in the parameter and bootup volume number do not match. • The status of the copy pair is invalid. • The status of the copy pair is being changed. 8D5B A BC Z copy pair cannot be Output dissolved. Possible reasons include one or more of the following: Not output • The status of the copy pair does not allow the status transition.
Table 57 Details of Error Codes 8Dxx (continued) Error Code Error Details 8D79 A TCA C/T group cannot be deleted. Possible reasons include one or more of the following: Type of Error BC Z Cnt Ac-S Z Not output TCA Cnt Ac-J Z CMD PATH Others Output Not output • The C/T group ID is incorrect. • The C/T group is not registered. • There is a TCA copy pair in the corresponding C/T group. • There is a copy pair that is being dissolved or suspended in the specified C/T group.
Table 58 Details of Error Codes 8Fxx Error Code Error Details 8F00 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH A Cnt Ac-J Z copy pair cannot be Not output made because the specified volume is an external volume. Output Not output 8F10 A Cnt Ac-J Z copy pair cannot be Not output made because the specified volume has been made as a copy pair for BC Z or FlashCopy and cannot be used for this combination.
Table 58 Details of Error Codes 8Fxx (continued) Error Code Error Details 8F24 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH A Cnt Ac-J Z copy pair cannot be Not output made because a path has not been established between the devices. Output Not output 8F25 A Cnt Ac-J Z copy pair cannot be made or resynchronized because the specified volume contains PIN data.
Table 58 Details of Error Codes 8Fxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Output Not output Others does not allow the status transition. (For example, the specified volume has already been made as a BC Z copy pair and cannot be used for this combination.) 8F58 A Cnt Ac-J Z copy pair cannot be Not output made or resynchronized. The reason might be one of the following: • The pair statuses of the specified S-VOL and P-VOL do not match.
Table 59 Details of Error Codes C0xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z Cnt Ac-S Z or TCA parameter does not match the storage system serial number or SSID of the RCU. C04D The serial number or SSID of the Not secondary storage system in the output Cnt Ac-S Z or TCA parameter does not match the storage system serial number or SSID of the RCU.
Table 59 Details of Error Codes C0xx (continued) Error Code Error Details C06D The P-VOL number in the Cnt Ac-S Z or TCA parameter does not match the bootup volume number. Type of Error BC Z Cnt Ac-S Z Not output Output Not output C06E The serial number or SSID of the Not primary storage system in the Cnt output Ac-S Z or TCA parameter does not match the storage system serial number or SSID of the local CU.
Table 59 Details of Error Codes C0xx (continued) Error Code Error Details C0C7 The command could not be executed because it is already in the SIMPLEX status. C0F1 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z Not output Output Not output The command to suspend could not Not be executed because the S-VOL for output Cnt Ac-S Z is in the Pending status.
Table 60 Details of Error Codes C1xx (continued) Error Code Error Details C12A Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others The command could not be Not output executed because the device-identifying code of an RCU for which path deletion is specified is invalid, or because the RCU type (FIBRE/ESCON) is invalid. Output Not output C12B The command could not be Not output executed because there are one or more paths that have a different serial number.
Table 60 Details of Error Codes C1xx (continued) Error Code Error Details Type of Error C194 A copy pair cannot be suspended Not because the S-VOL status is being output changed. Output Not output C195 A copy pair cannot be suspended Not because the specified copy pair is output already in the suspend status. Output Not output C198 The command cannot be executed Not because there is no copy pair that output can be suspended in the group.
Table 61 Details of Error Codes C2xx (continued) Error Code Error Details Type of Error C23E A copy pair cannot be suspended Not because the specified copy pair is output in the Pending status. Output Not output C28B Copy pair resynchronization, Not which causes a copy direction output reversal, cannot be made because the specified copy pair is not in the SWAPPING status.
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z be made because the Disaster Recovery Extended program product has not been installed in the RCU. C305 A copy pair cannot be made because the charging limit of Cnt Ac-S Z in the RCU has been exceeded. Check the license capacity of this and all related program products.
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details Type of Error C31D Formatting of the logical volume is Not being performed on the P-VOL. output Output Not output C31E The P-VOL is in the READ ONLY status. Not output Output Not output C320 The logical path between the MCU Not and the RCU is not set (number of output path = 0). Output Not output C321 The condition setting for the number Not of the Minimum Path between the output MCU and the RCU is invalid.
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details C336 Type of Error BC Z Cnt Ac-S Z The S-VOL has PIN data. Not output Output Not output C337 The S-VOL is in the Reserve status. Not output Output Not output C338 An intervention request has been issued for the S-VOL (S-VOL or reserve volume of BC Z). Not output Output Not output C339 The S-VOL is in the FCP status.
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details C37C Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z The subsystem level cache of the RCU is not valid. Not output Output Not output C37D The RCU is not NVS ON. Not output Output Not output C37E The device level cache of the S-VOL Not is not valid. output Output Not output C37F The S-VOL is not DFW ON. Not output Output Not output C380 The cache for the MCU is blocked Not on one side (in transition).
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details C3A5 The S-VOL is online. Type of Error BC Z Cnt Ac-S Z Not output Output Not output C3A6 The specified SSID, or CU number Not of RCU is incorrect. output Output Not output C3A8 A copy pair cannot be created Not because the specified copy pair is output made up of volumes whose emulation types are 3390-A and non-3390-A. Output Not output C3AA The RCU has its cache (one side) blocked (NVS).
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details Type of Error C3C0 When the P-VOL of a Cnt Ac-S Z Not or TCA copy pair is also the S-VOL output of a BC Z copy pair, both S-VOLs must be a copy pair in a one-to-one combination. C3C1 The S-VOL is not made under the C/T group. Not output Output Not output C3C2 The C/T group ID specified in making a copy pair is already in use in the S-VOL.
Table 62 Details of Error Codes C3xx (continued) Error Code Error Details Type of Error C3D3 The specified SSID, or CU number Not of the RCU is incorrect. output Output Not output C3D6 The specified S-VOL cannot be Not used because the device cannot be output recognized from the connection port. Output Not output C3D7 The status of the S-VOL in the RCU Not is incorrect.
Table 63 Details of Error Codes CBxx (continued) Error Code Error Details CB1D Type of Error BC Z Cnt Ac-S Z A dummy volume cannot be created on the S-VOL. Not output Output Not output CB1F The current RCU version does not support Fibre Cnt Ac-S Z or TCA. Not output Output Not output CB60 Fibre Cnt Ac-S Z or TCA has not been installed on the RCU. Not output Output Not output CB61 Copy pairs with Fibre and ESCON Not output paths cannot exist within the same C/T group.
Table 63 Details of Error Codes CBxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others Cnt Ac-J Z CMD PATH Others Not output Output Not output DB03 A Cnt Ac-J Z copy pair status Not output cannot be changed because the copy pair status is being changed (Suspending or Deleting). Output Not output DB07 A Cnt Ac-J Z copy pair status cannot be changed because the power-on process is in progress.
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Code Error Details DB08 A Cnt Ac-J Z copy pair status cannot be changed because the power-off process is in progress. Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output DB09 A Cnt Ac-J Z copy pair cannot be Not output made because the specified volume is a TCA copy pair.
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH 3390-9A and non-3390-9A in the specified journal group. E87B A Cnt Ac-J Z copy pair cannot be Not output made because the specified journal group is not registered. Output Not output E87C A Cnt Ac-J Z copy pair cannot be Not output made because a journal volume is not registered in the specified journal group.
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Code Error Details E891 A Cnt Ac-J Z copy pair cannot be made because the maximum number of copy pairs has already been registered in the specified M-JNL or R-JNL group. Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output E896 Registration to EXCTG has failed Not output because the Cnt Ac-J Z program product or the Disaster Recovery Extended program product has not been installed.
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others S-VOL for journal group do not match. E8A9 A Cnt Ac-J Z copy pair cannot be suspended because the storage system is being turned on. Not output Output Not output E8B6 A delta resync pair cannot be Not output made because the mirror ID of the specified R-JNL group is used by another Cnt Ac-J Z copy pair.
Table 65 Details of Error Codes EAxx (continued) Error Code Error Details EA07 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH A Cnt Ac-J Z copy pair cannot be Not output made because the number of copy pairs that can be registered in the specified M-JNL group has exceeded the maximum limit. Output Not output EA08 A Cnt Ac-J Z copy pair cannot be Not output made because the number of copy pairs that can be registered in the specified R-JNL group has exceeded the maximum limit.
Table 65 Details of Error Codes EAxx (continued) Error Code Error Details EA1E A resynchronization that reverses the copy direction for Cnt Ac-J Z copy pairs cannot be performed because the specified S-VOL is not the S-VOL of the Cnt Ac-J Z copy pair.
Table 65 Details of Error Codes EAxx (continued) Error Code Error Details Type of Error EA41 A Cnt Ac-J Z copy pair cannot be Not output made because the charging limit of the RCU program product has been exceeded. EA4D The Cnt Ac-J Z copy pair cannot be suspended because it is a delta resync pair. EA89 The status cannot be changed Not output from error status to the delta resync preparatory status, because the specified P-VOL is not in HOLDER status.
Table 65 Details of Error Codes EAxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Others capacity of this and all related program products. EAA6 A Cnt Ac-J Z copy pair cannot be Not output made because the charging limit of Cnt Ac-S Z in the MCU has been exceeded. Check the license capacity of this and all related program products.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output Not output Output Not output EB28 A Cnt Ac-J Z copy pair that is to Not output be linked with Cnt Ac-S Z cannot be made because the Disaster Recovery Extended program product has not been installed in the RCU. Output Not output EB30 A Cnt Ac-J Z copy pair status cannot be changed because the specified mirror ID is invalid.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH of the primary storage system does not match the actual serial number or SSID of the primary storage system. EB3D A Cnt Ac-J Z copy pair status Not output cannot be changed because the specified serial number or SSID of the secondary storage system does not match the actual serial number or SSID of the secondary storage system.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details EB5B Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH A Cnt Ac-J Z copy pair cannot be Not output made because the LDEV guard is set for the specified P-VOL or S-VOL. Output Not output EB5D A Cnt Ac-J Z copy pair cannot be Not output made because the LDEV security is set for the specified P-VOL or S-VOL.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details EB6F Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH A Cnt Ac-J Z copy pair cannot be Not output resynchronized because the micro version on the primary storage system does not support the 4x4 configuration. Output Not output EB70 A Cnt Ac-J Z copy pair cannot be Not output made because the S-VOL had already been paired by another program product.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details Type of Error EB87 A Cnt Ac-J Z copy pair cannot be Not output made. The reason might be one of the following: BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Output Not output Output Not output Others • The path from the secondary storage system to the primary storage system is not set. • The S-VOL is in the SIMPLEX status.
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details Type of Error EBBD The command could not be executed because the command device is under LDEV guard. Not output EBC6 A delta resync pair cannot be made because the S-VOL of the specified copy pair is used by another program product (BC Z/FlashCopy).
Table 66 Details of Error Codes EBxx (continued) Error Code Error Details EBE1 A delta resync cannot be executed because none of the S-VOLs of the delta resync pair are the S-VOLs of the other Cnt Ac-J Z. EBE2 Type of Error BC Z Cnt Ac-S Z TCA Cnt Ac-J Z CMD PATH Not output Output Not output A delta resync cannot be Not output executed because the differential bitmap information is not ready status to delta resync.
3 Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.
• Hitachi ShadowImage™ for Mainframe User's Guide: HP XP24000 Disk Array, HP XP20000 Disk Array • HP StorageWorks XP24000/XP20000 External Storage Software User’s Guide Manuals related to OS/390: • MVS Programming: Assembler Services Guide, GC28-1762 • MVS Setting Up a Sysplex, GC28-1779 • MVS System Codes, GC28-1780 • MVS System Commands, GC28-1781 • MVS Programming: Assembler Services Reference, GC28-1910 • Communications Server: IP User's Guide and Commands, GC31-8514 • Program Directory
• Communications Server IP Configuration Reference, SC31-8776 • Communications Server IP User's Guide & Commands, SC31-8780 • Communications Server IP API Guide, SC31-8788 • ISPF User's Guide Volume I, SC34-4822 • DFSMS Advanced Copy Services, SC35-0428 You can find these documents on the HP Manuals website: http://www.hp.com/support/manuals In the Storage section, click Storage Software and then select a product.
Typographic conventions Table 67 Document conventions Convention Element Blue text: Table 67 (page 237) Cross-reference links Blue, bold, underlined text email addresses Blue, underlined text: http://www.hp.
Glossary A API Application programming interface. B BC Manager A generic name for the following products: • P9000 for Business Continuity Manager Software • HP StorageWorks P9000 for Business Continuity Manager Extended CT Group • P9000 for Bus Continuity Manager Universal Replicator 4x4 Extended CT Software C CCA Command control address. CSB Channel status byte. CU Control unit. D DAD Device address domain. DASD Direct access storage device. DBCS Double byte character set.
M M-JNL Master journal. Mainframe Agent HP Device Manager Mainframe Agent. MCU Main control unit. MIH Missing interrupt handler. P P-VOL Primary volume. PPRC Peer-to-peer remote copy. PSW Program status word. R R-JNL Restore journal. RACF Resource access control facility. RCU Remote control unit. RECFM Record format. REXX Restructured extended executor. S S-VOL Secondary or remote volume. The copy volume that receives the data from the primary volume.
Z z/Linux 240 Glossary Linux on IBM System z.