HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
The main task or subtask terminated abnormally during BCM
Monitor processing. If the task cannot be recovered, BCM Monitor
will stop.
BCM Monitor function
abend: code=Sxxx Uxxxx
abended-module=module-name
C-Date=module-creation-date
YK8028E CON
Contact the center administrator.
base=bbbbbbbb disp=dddd Sxxx (hexadecimal number)
[calling-module=module-name
C-Date=y'y'.m'm'.d'd'
System completion code when the task
terminated abnormally
base=bbbbbbbb
disp=dddd]
Uxxxx (decimal number)
User completion code when the task terminated
abnormally
PSW=pppppppp pppppppp
ILC=ll INTC=xx
Registers at time of failure
module-name
GR 00-03
contents-of-register-0
Section name of the BCM Monitor module or
load module name.
contents-of-register-1
If the module cannot be identified, UNKNOWN is
displayed. In this case, the values of
y'y'.m'm'.d'd' and bbbbbbbb are invalid.
contents-of-register-2
contents-of-register-3
GR 04-07
contents-of-register-4
module-creation-date
contents-of-register-5
This is displayed in one of the following formats:
contents-of-register-6
contents-of-register-7
y'y'.m'm'.d'd': Creation date of the module identified by
module-name
GR 08-11
contents-of-register-8
y'y'/m'm'/d'd': Creation date of the module identified by
module-name
contents-of-register-9
bbbbbbbb
contents-of-register-10
contents-of-register-11
Contents of the base register
GR 12-15
contents-of-register-12
dddd
contents-of-register-13
ABENDED-MODULE: Location where ABENDED-MODULE was
called, relative to the top of the module
contents-of-register-14
contents-of-register-15
CALLING-MODULE: Location where CALLING-MODULE was
called, relative to the top of the module
pppppppp pppppppp
PSW during the abnormal termination
ll
Length of the command during the abnormal
termination
xx
Interrupt code during the abnormal termination
The value identified by error-type, which was specified in the
command-name command, is invalid.
The specified error-type is
invalid: command-name.
YK8031W CON
error-type
label: The label name is invalid. Check the label name for
ACTION=STOPPOINT specified in the YKMONCG file.
copy group: The copy group ID is invalid. Check the copy
group ID for CGID specified in the YKMONCG file.
BCM Monitor will stop at the point label.time BCM Monitor will stop
at STOPPOINT 'label'.
YK8040I PRT CON
time
Message output time
List of Messages 11