HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKY7x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
version: A version error
Make sure that the definition
information version is correct.
YKP2A: A definition-creation
program error
The requested operation cannot
be performed because the
configuration file of the copy
group cgname was created by
the Mainframe Agent YKP2A
command.
The user does not have authorization to perform the
requested operation.
This request cannot be executed
without valid authorization.
YKY727E XML
Change the MODE parameter in the initialization
parameters to EDIT, and then retry the operation.
The information of the configuration file has been
updated since it was last obtained.
The information in configuration file
was updated after you obtained it.
YKY728E XML
Refresh the configuration file from Replication
Manager, and then retry the operation.
The contents of the configuration file are invalid.Configuration file is invalid. fileYKY729E XML
See the other error message that was output with this
message, and then use Replication Manager to correct
the error. After that, update the configuration file
again.
file
Name of the configuration file in
which an error was detected
The specified consistency group is invalid.INVALID CT Group is specified.YKY730E XML
Make sure that the specified consistency group exists
in the copy group definition file.
A REXX script that cannot be used by Mainframe
Agent was executed.
MFAgent cannot use this REXX exec
library.
YKY999E TSO CON
Check the REXX Exec library connected to SYSEXEC
dd name.
Table 35 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ0x)
Explanation and Recommended ActionsMessage TextMessage ID
Invalid parameters were specified.Supplied parameters invalidYKZ000T TSO SC=48
For details, see the reason code in the YKZ099I
message displayed after this message. For more
information about reason codes, see IKJPARS in the
TSO/E Programming Services.
Nothing is assigned to the parameter identified by
parameter-name.
No parameter-name() suppliedYKZ001E TSO MSG
SC=48
List of Messages 113