HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ10x YKZ20x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
The command cannot be executed because a Core
processing error occurred.
A Core process error occurred.
(detail=message-text, cmd=xxx,
pos=yyy)
YKZ207E MSG TSO
CON SC=52 RC=44
#
message-text (string)
Message text
The message text will be as shown
below:
If an OS macro error occurred:
xxxxxxxx macro error,
return code = rr, devn =
dddd
xxxxxxxx: OS macro name
rr: Return code from the macro
dddd: device number
If system name acquisition
failed:
ASASYMBM macro error,
rc = rr
rr: Return code of ASASYMBM
macro
If the log stream definition is not
DASD-dedicated:
Not DASD-only Logger
definition
If the MAXBUFSIZE of the log
stream definition is not 64000:
MAXBUFSIZE of Logger
definition invalid
If this message is displayed as
maintenance information (1):
ENTRYID ( eeeee ) for
MSGID ( nnn ) is
invalid
eeeee, nnn: Maintenance
information
If this message is displayed as
maintenance information (2):
ENTRYID ( eeeee ) for
TYPE ( ttt ), LEVEL ( lll
) is invalid
eeeee, ttt, lll: Maintenance
information
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code description
in the explanation of the YKZ201E
message.
yyy (string)
118 Messages