HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ21x YKZ24x)
Explanation and Recommended ActionsMessage TextMessage ID
The command cannot be executed because a
NAME/TOKEN read error occurred.
A NAME/TOKEN read error
occurred. (return code=nnn, name=
name, cmd=xxx, pos=yyy)
YKZ210E MSG TSO
CON SC=40 RC=44
#
Check that the YKLOAD command terminated
normally.
nnn (decimal number)
Return code set by the
NAME/TOKEN read routine
(IEANTRT)
name (string)
Name registered in the
Name/Token service
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
#
If this message is output when the log and trace
are obtained, the RC is 0.
The command cannot be executed because a
NAME/TOKEN write error occurred.
A NAME/TOKEN write error
occurred. (return code=nnn, name=
name, cmd=xxx, pos=yyy)
YKZ211E MSG CON
SC=40 RC=44
#
nnn (decimal number)
Return code set by the
NAME/TOKEN registration routine
(IEANTCR)
name (string)
Name registered in the
Name/Token service
xxx (decimal number)
Command code of the command
that was executing when the error
occurred
See the command code
description in the explanation of
the YKZ201E message.
yyy (string)
Maintenance information
#
If this message is output when the log and trace
are obtained, the RC is 0.
A FREEMAIN error occurred.A FREEMAIN error occurred. (return
code=nnn, cmd=xxx, pos=yyy)
YKZ212W CON
#
RC=0
nnn (decimal number)
Return code of the FREEMAIN
macro
120 Messages