HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
performed after the storage system microcode was
replaced, perform another scan.
value
IFType value of the remote
storage system
The IFType of a storage system using the Remote
DKC Control Function is smaller than the IFType of
Secondary volume's IFType is larger
than Remote control's IFType value.
YKZ280W MSG SC=0
RC=0
the S-VOL defined in the copy group. As such, the
smaller of the two will be used when each command
is executed. Note that on some machine types, some
functionality might be lost. Also, if a scan was not
performed after the storage system microcode was
replaced, perform another scan.
value
IFType value of the remote
storage system
The device specified during command device usage
does not support the remote DKC control function.
Some of the storage systems do not
support Remote Control.
YKZ281E MSG SC=36
RC=36
#1
(Storage
System's-IFType)
Check whether the device can use the remote DKC
control function
#2
, and then revise the remote DKC
control function definitions.
Storage System's-IFType
IFType value of the storage
system
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The remote DKC control function can be used in
a storage system on the Lightning storage system
models (or later) where the first two digits of the
IFType are X'04' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has a P-VOL or uses the remote DKC control function.
Primary device IFType does not
support CAJ.
YKZ282E MSG SC=36
RC=36
#1
Use a device
#2
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has an S-VOL or uses the remote DKC control
function.
Secondary device IFType does not
support CAJ.
YKZ282E MSG SC=36
RC=36
#1
Use a device
#2
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
140 Messages