HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
subCTGroupID in the copy group structure is either
NULL or invalid.
subCTGroupID value null or invalid.YKZ283T MSG SC=36
RC=36
#
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Cnt Ac-J Z_MirrorID in the copy group structure
is either NULL or invalid.
CAJ value null or invalid.YKZ284T MSG SC=36
RC=36
#
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The YKBLDPTH, YKDELPTH, and YKQRYPTH
commands cannot be executed for a logical path
This command cannot be executed
without a port.
YKZ285I MSG SC=0
RC=0 (index)
without a port element both on primary and
secondary direction. Only the YKQRYPTH command
with a RESTRUCT parameter can be executed on a
logical path without a port element.
To execute one of these commands against a logical
path, correct the configuration file and then execute
the YKLOAD command.
index
Index number of the logical path
without a port element
When the YKQRYPTH command is executed on a
storage system that has not been directly connected
YKQRYPTH command cannot be
executed if the volume on the CU
type path has not been scanned.
YKZ286E MSG SC=36
RC=36 (index)
to the host for the path set of an inter-control unit
logical path, the volume belonging to the originally
established inter-control unit of the inter-control unit
logical path must have been scanned at least once.
Make sure that the volume belonging to the targeted
control unit has been scanned at least once, and the
control unit and command control address defined
for the path set are correct. If the command control
address is not defined for the path set, from the Edit
Logical Path Definition panel, specify the command
control address of the volume scanned in the target
control unit for path control.
index
Index number of the logical path
that cannot be executed
List of Messages 141