HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ29x)
Explanation and Recommended ActionsMessage TextMessage ID
The FROMCU has exceeded the maximum number of
CUs that are supported by storage systems.
FROMCU() exceeds number of CU
that storage systems supported.
YKZ290E MSG SC=48
RC=48
Specify the maximum supported number of CUs or
less.
The log dataset is full.The log dataset is full. (DSN=ddd,
cp=xxx:yyy)
YKZ291I CON SC=0
RC=0
ddd
Name of the log dataset that
became full
If a log dataset name cannot be
collected, * is displayed.
xxx (decimal number)
Command code for the command
that was executing when the log
dataset became full
See the description for the
command code in the YKZ201E
message.
yyy (string)
Maintenance information
The log dataset was switched.The log dataset was switched.
(from=YKLOGmm, to=YKLOGnn,
job=jjj, cp=xxx:yyy)
YKZ292I CON SC=0
RC=0
YKLOGmm
Previous log dataset (YKLOG01 or YKLOG02)
YKLOGnn
New log dataset (YKLOG01 or YKLOG02)
jjj
Job name
xxx (decimal number)
Command code for the command
that was executing when the log
dataset was switched
See the description for the
command code in the YKZ201E
message.
yyy (string)
Maintenance information
The value specified for the &YKLOGPT system symbol
is invalid. The program continues processing while
assuming LOGR.
The specified value for the system
symbol &YKLOGPT is invalid.
YKZ293E MSG CON
SC=0 RC=0
Revise the value specified for the &YKLOGPT system
symbol.
An error occurred while acquiring the &YKLOGPT
system symbol. The program continues processing
while assuming LOGR.
An error occurred while acquiring
the system symbol &YKLOGPT. (rc=rr)
YKZ294E MSG CON
SC=0 RC=0
Revise the value specified for the &YKLOGPT system
symbol.
rr
142 Messages