HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
param-name
Name of the required parameter
Specify the CGID parameter at the beginning of the copy group
parameters in the YKMONCG file.
time CGID parameter must
be specified first : rec#.
YK8079E PRT
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
rec#
Line number where the error was detected
The copy group cgid is specified more than once in the YKMONCG
file.
time Duplicate CGID
parameters found : cgid.
YK8080E PRT
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
cgid
CGID parameter value that is specified more
than once
The combination of STATUS and ACTION specified in the
YKMONCG file is invalid.
time Combination of STATUS
and ACTION is invalid :
rec#.
YK8081E PRT
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
rec#
Line number where the error was detected
The combination of NOCANCEL and the startup status specified for
the CGSTARTUPSTATUS parameter in the YKMONCG file is invalid.
time Combination of Startup
Status and NOCANCEL is
invalid : rec#.
YK8082E PRT
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
rec#
Line number where the error was detected
The copy group cgid specified in the ACTION parameter of the
YKMONCG file is not defined.
time The corresponding
CGID parameter is not
defined : cgid.
YK8083E PRT
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
cgid
16 Messages