HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

2 Storage System Sense Byte Information
This chapter describes storage system sense byte information (error codes) contained in messages
that are output by Business Continuity Manager.
Details of Error Codes
This section lists the details on the storage system sense byte information (error codes) that are
output to messages. If an error code not listed in this table is output, contact service representative.
The legend is as follows:
CMD: Command device
PATH: Logical path
Output: Produces output
Not output: Produces no output
Table 47 Details of Error Codes 20xx 22xx
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputA BC Z copy pair cannot be made or
resynchronized. The reason might be
one of the following:
The BC Z copy pair status cannot
be changed because the P-VOL
has already been made into a
copy pair by using Cnt Ac-J Z.
2060
Not outputOutputAn BC Z copy pair cannot be made.
The reason might be one of the
following:
2061
The S-VOL has already been made
into a copy pair by using Cnt Ac-J
Z
The S-VOL is a journal volume.
Not outputOutputAn BC Z copy pair cannot be
resynchronized because the specified
2067
volume is part of a Cnt Ac-S Z and
Cnt Ac-J Z common volume
configuration and neither the Cnt Ac-S
Z nor Cnt Ac-J Z copy pair are in the
suspend status.
Not outputOutputA BC Z copy pair could not be made
because the status of the P-VOL for
2078
the specified BC Z copy pair does not
meet all of the following conditions:
The S-VOL is part of a delta resync
pair
The delta resync pair is in the
HOLD status
A Cnt Ac-J Z copy pair that is
linked with the delta resync pair is
in the suspend status
Not outputOutputThe BC Z copy pair could not be
made because the specified S-VOL of
2079
Details of Error Codes 163