Table 47 Details of Error Codes 20xx 22xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputA copy pair could not be created
because the P-VOL of the specified
20BD
BC Z copy pair is an emulation type
(3390-V) that is not supported.
Not outputOutputA copy pair could not be created
because the S-VOL of the specified
20BE
BC Z copy pair is an emulation type
(3390-V) that is not supported.
Not outputOutputIf the emulation type of the P-VOL of
the specified BC Z copy pair is
20C9
3390-A, a copy pair could not be
created for one of the following
reasons:
No mainframe Fibre Channel
adapter is installed.
All of the mainframe Fibre Channel
adapters are blocked.
Not outputOutputIf the emulation type of the S-VOL of
the specified BC Z copy pair is
20CA
3390-A, a copy pair could not be
created for one of the following
reasons:
No mainframe Fibre Channel
adapter is installed.
All of the mainframe Fibre Channel
adapters are blocked.
Not outputOutputA copy pair could not be created
because the pool of the THP Z volume
20D0
specified for the P-VOL of the BC Z
copy pair is being initialized.
Not outputOutputA copy pair could not be created
because the pool of the THP Z volume
20D1
specified for the S-VOL of the BC Z
copy pair is being initialized.
Not outputOutputA copy pair could not be created for
one of the following reasons:
20D6
The P-VOL of the specified BC Z
copy pair is being used for
Compatible FlashCopy.
The P-VOL of the specified BC Z
copy pair is a TSE-VOL.
Not outputOutputA copy pair could not be created for
one of the following reasons:
20D7
The S-VOL of the specified BC Z
copy pair is being used for
FlashCopy SE.
The S-VOL of the specified BC Z
copy pair is a TSE-VOL.
Not outputOutputA BC Z copy pair cannot be made
because the specified P-VOL is an
S-VOL for FlashCopy.
22F6
Details of Error Codes 165