HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 48 Details of Error Codes 23xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputThe command could not be executed
because the S-VOL of a BC Z copy
pair is online.
2312
Not outputOutputAn BC Z copy pair cannot be
suspended because the copy pair is
in the Split status.
2313
Not outputOutputA BC Z copy pair cannot be made
because the copy pair is in the Split
status.
2314
Not outputOutputA BC Z copy pair status cannot be
changed. The reason might be one of
the following:
231B
The status of another copy pair
that shares the P-VOL is SUSPVS.
There is a FlashCopy pair that
shares the P-VOL.
Not outputOutputA BC Z copy pair cannot be
resynchronized because the P-VOL is
online.
231F
Not outputOutputA BC Z copy pair cannot be made
because the charging limit of the
program product was exceeded.
232A
Not outputOutputA BC Z copy pair cannot be made.
The reason might be one of the
following:
2331
P-VOL is a Reserve volume.
The volume size of P-VOL differs
from that of S-VOL.
The SM capacity is insufficient for
copy pair creation.
Not outputOutputA BC Z copy pair status cannot be
transitioned because the maximum
2332
multiplicity of the copy pairs for the
P-VOL was exceeded.
Not outputOutputA BC Z copy pair cannot be
suspended or dissolved because the
copy pair is in the SIMPLEX status.
2333
Not outputOutputA BC Z copy pair cannot be made
because the emulation type of the
specified volume is not supported.
2334
Not outputOutputA BC Z copy pair cannot be made
because the RAID level or emulation
type of the volume is not supported.
2335
Not outputOutputA BC Z copy pair status cannot be
changed because the combination of
2336
the drive emulation type of the P-VOL
and S-VOL is not appropriate.
Not outputOutputA BC Z copy pair status cannot be
changed because the volume
2337
Details of Error Codes 167