HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 48 Details of Error Codes 23xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputA BC Z copy pair status cannot be
changed. The reason might be one of
the following:
2358
The status of another copy pair
that shares the P-VOL or S-VOL is
TRANS.
There is a FlashCopy pair that
shares the P-VOL or S-VOL.
Not outputOutputA BC Z copy pair cannot be
resynchronized with Reverse or Quick
235B
specified because the P-VOL is the
P-VOL of a Cnt Ac-S Z or TCA copy
pair that is not in the suspend status.
Not outputOutputA BC Z copy pair cannot be
resynchronized with Reverse or Quick
235C
specified because the P-VOL is the
S-VOL of a Cnt Ac-S Z or TCA copy
pair that is not in the suspend status.
Not outputOutputA BC Z copy pair cannot be
resynchronized with Reverse or Quick
235D
specified because the S-VOL is the
P-VOL of a Cnt Ac-S Z or TCA copy
pair that is not in the suspend status.
Not outputOutputA BC Z copy pair status cannot be
changed because the specified
volume is not installed.
2370
Not outputOutputA BC Z copy pair cannot be made
because the volume specified to be
2371
the P-VOL is a ystem residence
volume.
Not outputOutputA BC Z copy pair status cannot be
changed because the volume
2373
specified to be the P-VOL is a
command device.
Not outputOutputA BC Z copy pair cannot be
resynchronized (QuickRestore)
237B
because all of the following conditions
exist:
The specified P-VOL is an internal
volume.
The specified S-VOL is an external
volume.
The specified P-VOL has a shared
configuration with the P-VOL of the
Cnt Ac-S Z.
Not outputOutputA BC Z copy pair cannot be made
because the volume specified to be
2381
the S-VOL is a system residence
volume.
Not outputOutputA BC Z copy pair status cannot be
changed because the volume
2383
Details of Error Codes 169