HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 50 Details of Error Codes 37xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot outputA delta resync pair cannot be
executed. The reason might be one
of the following:
3707
The command target volume is the
P-VOL of a Cnt Ac-S Z copy pair
and the copy pair status is not
Duplex.
The command target volume is the
S-VOL of a Cnt Ac-S Z copy pair
and the copy pair status is not
SSWS.
Not outputOutputNot outputThe delta resync command cannot be
executed because there are no Cnt
3709
Ac-J Z copy pairs with a mirror ID
other than the one specified for the
delta resync pair in the specified
R-JNL group.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
resynchronized (with the DELTAJNL
370B
parameter) because the specified
P-VOL is not in the HOLD status or
HOLDTRNS status. Alternatively, a
Cnt Ac-J Z copy pair cannot be
resynchronized (with the ALLJNL
parameter) because the specified
P-VOL is not in the HOLD status,
HOLDTRNS status, or NODELTA
status.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made (with the HOLD parameter) or
370C
resynchronized (with the DELTAJNL
parameter or ALLJNL parameter).
The reason might be one of the
following:
The specified M-JNL group or R-JNL
group does not allow the status to
be changed.
The specified M-JNL group or R-JNL
group is in progress of the status
to be changed.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
resynchronized (with the PREPARE
370D
parameter) because the journal
volume cannot be accessed.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
resynchronized (with the PREPARE
3711
parameter) because the journal
volume is blocked.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made or resynchronized because the
journal volume in M-JNL is blocked.
3720
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the volume specified
3726
174 Storage System Sense Byte Information