HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 51 Details of Error Codes 46xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set because three
4668
generations of suspend time have
already been set for the specified
R-JNL group.
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set because another
4669
suspend time has already been set
for the C/T group of the specified
BC Z copy pair.
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set. The reason might be
one of the following:
466A
The specified time is earlier than
the consistency time.
The timer type remains Local
because the Cnt Ac-J Z copy pair
has not been resynchronized
after the timer type was changed
from Local to System.
When changing the timer type from
Local to System, you need to
suspend the Cnt Ac-J Z copy pair. If
the CAJ ATTIME suspend time has
already been set, perform the
following procedure to set the CAJ
ATTIME suspend time again.
Suspend the Cnt Ac-J Z copy pair.
Change the timer type.
Resynchronize the Cnt Ac-J Z copy
pair.
Set the CAJ ATTIME suspend time
again.
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set because the C/T
466B
group ID of the specified BC Z copy
pair is incorrect.
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set because the specified
4678
volume is not an BC Z copy pair or
the specified C/T group ID is not
matched.
Not outputOutputNot outputThe NORMAL ATTIME suspend time
cannot be set because the CAJ
467A
ATTIME suspend time has already
been set for the specified BC Z C/T
group.
Not outputOutputNot outputThe CAJ ATTIME suspend time
cannot be set because the NORMAL
467B
ATTIME suspend time has already
been set for the specified BC Z C/T
group.
Details of Error Codes 179