HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 54 Details of Error Codes 4Bxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
specified. The reason might be one
of the following:
The specified volume is not in a
Cnt Ac-S Z copy group with a
C/T group ID specified.
The specified volume is using the
Open/MF Consistency
Preservation Function.
The copy pair is in the SIMPLEX
status.
Not outputOutputNot
output
A copy pair cannot be created or
resynchronized because the
4B32
specified P-VOL satisfies one of the
following conditions:
The P-VOL is being used for
FlashCopy.
The P-VOL is being used for
FlashCopy SE.
The P-VOL is a TSE-VOL.
Not
output
OutputNot outputA path cannot be set because the
CU number for the specified MCU
is not supported.
4B35
Not
output
OutputNot outputA path cannot be set because the
port number for the specified MCU
is not supported.
4B36
Not
output
OutputNot outputA path cannot be set because the
port number for the specified RCU
is not supported.
4B37
Not
output
OutputNot outputA path cannot be set because the
CU number for the specified RCU is
not supported.
4B38
OutputNot outputThe remote command cannot be
executed because the path between
4B49
the specified storage system or CU
(SSID) and the command target
storage system is not set, or an error
has occurred on the path.
Not outputOutputNot
output
The following copy pairs cannot be
made because the specified volume
is a FlashCopy pair:
4B85
A Cnt Ac-S Z copy pair that
specified a C/T group
A TCA copy pair that specified
a C/T group
Not outputOutputNot
output
A Cnt Ac-S Z copy pair cannot be
made because the specified volume
4B86
is a FlashCopy pair and
differential-data management unit is
cylinder.
Details of Error Codes 185