HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 57 Details of Error Codes 8Dxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not
output
OutputNot outputOutputA copy pair cannot be made. The
reason might be one of the
following:
8D10
An inter-CU logical path has not
been set between the specified
CUs.
The storage system serial
number of the P-VOL is
incorrect.
The SSID of the P-VOL is
incorrect.
The CU number is not
supported.
Not outputOutputNot outputThe command could not be
executed because the volume
8D11
specified by the host command
parameter is in the NOT READY
status.
Not outputOutputNot outputThe command could not be
executed because the logical
8D12
volume of the specified volume by
the host command parameter is
blocked.
Not outputOutputThe command could not be
executed because the BC Z, Cnt
8D14
Ac-S Z, or TCA program product
is not installed.
Not outputOutputA BC Z copy pair cannot be made
or resynchronized. Possible reasons
8D15
include one or more of the
following:
The status of the copy pair does
not allow the status transition.
For details, see error code
2310.
The charging limit of the
program product was
exceeded.
The copy pair is in the Pending
status.
The copy pair is not in the Split
status.
The specified C/T group ID is
not registered.
Not outputOutputA BC Z copy pair cannot be made
or resynchronized. Possible reasons
8D16
include one or more of the
following:
The status of the copy pair does
not allow the status transition.
192 Storage System Sense Byte Information