HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 57 Details of Error Codes 8Dxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
For details, see error code
2310.
The charging limit of the
program product was
exceeded.
The copy pair is in the Pending
status.
The copy pair is not in the Split
status.
The specified C/T group ID is
not registered.
Not outputOutputThe command could not be
executed because the BC Z, Cnt
8D17
Ac-S Z, or TCA program product
is not installed.
Not outputOutputNot
output
The command could not be
executed because the volume
8D1A
specified by the host command
parameter is the S-VOL.
Not outputOutputNot
output
A status cannot be changed
because the status of the specified
8D1B
copy pair does not match the
actual status.
Not outputOutputNot
output
A Cnt Ac-S Z or TCA copy pair
cannot be made or resynchronized.
8D1C
Possible reasons include one or
more of the following:
The P-VOL is a command
device.
The specified serial number of
the primary storage system or
SSID does not match the storage
system serial number or SSID of
the local CU.
The specified P-VOL does not
match the bootup volume.
The C/T group ID is incorrect.
The P-VOL has not been made
in the corresponding C/T
group.
The S-VOL is not in the Reverse
Resync status.
Either C/T group ID or the C/T
group timer type is incorrect.
Not outputOutputA BC Z copy pair cannot be made
or resynchronized. Possible reasons
8D1D
include one or more of the
following:
The S-VOL is online.
The status of the copy pair does
not allow the status transition.
Details of Error Codes 193