HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 57 Details of Error Codes 8Dxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
The status is invalid.
The status of the copy pair is
being changed.
Not outputOutputA BC Z copy pair cannot be
suspended. Possible reasons
8D2A
include one or more of the
following:
The status of the copy pair does
not allow the status transition.
For details, see error code
2310.
The copy pair is in the SIMPLEX
status.
The copy pair is in the Split
status.
The specified C/T group ID is
not registered.
OutputNot outputThe serial numbers for the primary
and the secondary storage systems
8D2C
in the host command parameter is
incorrect.
OutputNot outputThe host command parameter is
incorrect.
8D30
Not outputOutputMultiple BC Z copy pairs cannot
be suspended because there is a
8D31
copy pair that does not allow the
status transition in the specified
copy pairs.
Not outputOutputNot outputThe command could not be
executed because the specified
volume is not in the SIMPLEX status.
8D38
Not outputOutputNot outputA command device cannot be
defined because it differs from the
APID that was already registered.
8D39
Not outputOutputNot outputA command device cannot be
defined because the specified APID
is in use by another DEV.
8D3A
Not outputOutputNot outputA command device cannot be
deleted because the specified
volume is not a command device.
8D3D
Not outputOutputNot outputA command device cannot be
made because the specified CU
number is not supported.
8D3E
Not outputOutputNot outputThe command cannot be executed
because the volume specified as
8D41
the command device is already
part of a copy pair, or is a journal
volume.
Not outputOutputNot outputThe command cannot be executed
because the volume specified as a
8D42
196 Storage System Sense Byte Information