Table 57 Details of Error Codes 8Dxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
• The S-VOL number in the
parameter and bootup volume
number do not match.
• The status of the copy pair is
invalid.
• The status of the copy pair is
being changed.
Not outputOutputA BC Z copy pair cannot be
dissolved. Possible reasons include
one or more of the following:
8D5B
• The status of the copy pair does
not allow the status transition.
For details, see error code
2310.
• The copy pair is in the V-Split
status.
• The specified C/T group ID is
not registered.
OutputNot outputThe host command parameter is
incorrect.
8D70
Not outputOutputNot outputA TCA C/T group cannot be
registered or changed. Possible
8D71
reasons include one or more of the
following:
• The specified C/T group ID is
incorrect.
• You cannot specify System as
the timer type.
• The timer type is incorrect (not
System, Local, or None).
• The C/T group ID is already
registered.
• The C/T group ID is not
registered.
• The timer type (System,
Local, or None) cannot be
changed because there is a
copy pair in the specified C/T
group.
• There is a copy pair in the
corresponding C/T group that
has a status that is neither
SIMPLEX nor suspend.
• The copy types of the specified
C/T group and the types of
bootup C/T group do not
match.
OutputNot outputThe host command parameter is
incorrect.
8D78
Details of Error Codes 199