Table 57 Details of Error Codes 8Dxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot outputA TCA C/T group cannot be
deleted. Possible reasons include
one or more of the following:
8D79
The C/T group ID is incorrect.
The C/T group is not registered.
There is a TCA copy pair in the
corresponding C/T group.
There is a copy pair that is
being dissolved or suspended
in the specified C/T group.
OutputNot outputThe host command parameter is
incorrect.
8D80
Not outputOutputA BC Z copy pair cannot be made,
resynchronized, or suspended
8DD1
because the CAJ ATTIME suspend
time has been set for the specified
BC Z C/T group.
OutputNot outputThe command could not be
executed because the
sub-command code is incorrect.
8DF0
OutputNot outputThe host command parameter is
incorrect.
8DF1
OutputNot outputThe command could not be
executed because the specified
8DF2
volume is either not a TCA volume,
or not the P-VOL.
Not outputOutputNot outputThe command could not be
executed because the specified
8DF3
volume is in the NOT READY
status.
Not outputOutputNot outputThe command could not be
executed because the logical
8DF4
volume of the specified volume is
blocked.
OutputNot outputThe command could not be
executed because the SSID and CU
8DF5
number in the host command
parameter do not match.
OutputNot outputThe command could not be
executed because the serial
8DF6
numbers of the host command
parameter and the local storage
system do not match.
OutputNot outputThe command could not be
executed because the SSID of the
8DF7
host command parameter and the
local storage system do not match.
OutputNot outputThe command could not be
executed because the
sub-command code is incorrect.
8DFF
200 Storage System Sense Byte Information