HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 62 Details of Error Codes C3xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
be made because the Disaster
Recovery Extended program
product has not been installed in
the RCU.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of Cnt
C305
Ac-S Z in the RCU has been
exceeded. Check the license
capacity of this and all related
program products.
Not outputOutputNot
output
A copy pair cannot be made
because the charging limit of TCA
C306
in the RCU has been exceeded.
Check the license capacity of this
and all related program products.
Not outputOutputNot
output
The specified volume within the
RCU, or another volume which
C30D
belongs to the same group is in
transition to a SIMPLEX or suspend
status. Try the operation again in
a few minutes.
Not outputOutputNot
output
The MCU is not NVS ON.C310
Not outputOutputNot
output
The subsystem level cache of the
MCU is not valid.
C311
Not outputOutputNot
output
The P-VOL is not in the SIMPLEX
status.
C312
Not outputOutputNot
output
The P-VOL is not in the suspend
status.
C313
Not outputOutputNot
output
The P-VOL is not in the SIMPLEX
status.
C314
Not outputOutputNot
output
The P-VOL has PIN data.C315
Not outputOutputNot
output
The drive copy is being performed
on the P-VOL (troubleshooting).
C316
Not outputOutputNot
output
The drive copy is being performed
on the P-VOL (SVP request).
C317
Not outputOutputNot
output
The copy task ending process is
being performed on the P-VOL.
C318
Not outputOutputNot
output
The collection copy is being
performed on the P-VOL.
C319
Not outputOutputNot
output
The P-VOL is in a collection access
status.
C31A
Not outputOutputNot
output
The logical volume of the P-VOL is
blocked (PDEV blocking factor).
C31B
Not outputOutputNot
output
The P-VOL cannot be accessed
(because the LDEV is blocked or in
the NOT READY status).
C31C
210 Storage System Sense Byte Information