HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 62 Details of Error Codes C3xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot
output
When the P-VOL of a Cnt Ac-S Z
or TCA copy pair is also the S-VOL
C3C0
of a BC Z copy pair, both S-VOLs
must be a copy pair in a one-to-one
combination.
Not outputOutputNot outputThe S-VOL is not made under the
C/T group.
C3C1
Not outputOutputNot outputThe C/T group ID specified in
making a copy pair is already in
use in the S-VOL.
C3C2
Not outputOutputNot outputThe 4MCU is already registered or
made under the subjected C/T
group.
C3C3
Not outputOutputNot outputThe option information (timer type,
timeout) for an operating (already
C3C4
being made a copy pair) C/T
group cannot be changed.
Not outputOutputNot outputA copy pair could not be made
because there are multiple storage
C3C5
systems at the primary site, but the
timer type is not System.
Not outputOutputNot outputThe command cannot be executed
because the update timeout option
C3C6
is different for copy pairs that
already exist and those that have
not yet been made on the primary
site that has multiple storage
systems.
Not outputOutputNot
output
A Cnt Ac-S Z or TCA copy pair
cannot be made. The reason might
be one of the following:
C3C7
The specified volume is part of
a Cnt Ac-S Z, TCA, or Cnt Ac-J
Z copy pair with another
volume.
The specified volume is a
journal volume.
Not outputOutputNot outputThe C/T group is not registered in
the RCU.
C3C9
Not outputOutputNot
output
The S-VOL is in the reserve status
or the RCU, the S-VOL or the M-R
path is in the BUSY status.
C3CA
Not outputOutputNot outputThe TCA program product has not
been installed on the RCU.
C3CB
Not outputOutputNot
output
The S-VOL of a Cnt Ac-S Z or TCA
copy pair is a BC Z pair volume.
C3CD
Not outputOutputNot outputAnother C/T group ID is already
registered or made in the RCU.
C3D1
Not outputOutputNot
output
The storage system type of the RCU
is not supported by Cnt Ac-S Z or
TCA.
C3D2
Details of Error Codes 215