HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 63 Details of Error Codes CBxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot
output
A dummy volume cannot be
created on the S-VOL.
CB1D
Not outputOutputNot
output
The current RCU version does not
support Fibre Cnt Ac-S Z or TCA.
CB1F
Not outputOutputNot
output
Fibre Cnt Ac-S Z or TCA has not
been installed on the RCU.
CB60
Not outputOutputNot outputCopy pairs with Fibre and ESCON
paths cannot exist within the same
C/T group.
CB61
Not outputOutputNot
output
Copy pairs with Fibre and ESCON
paths cannot exist within the same
storage system.
CB62
Not outputOutputNot
output
The storage system type of the
MCU is not supported (not
3990-6/6E, or is 2105).
CB64
Not outputOutputNot outputThe upper limit of 4,096 (or more)
copy pairs cannot be made within
the same C/T group by RCU.
CB69
Not outputOutputNot
output
A copy pair cannot be made
because the specified S-VOL is
defined as a command device.
CB78
Not outputOutputNot
output
A Cnt Ac-S Z or TCA copy pair
cannot be made because the CLPR
CB7E
that the specified S-VOL belongs to
differs from the one registered in
the C/T group. For details on the
CLPR, see the storage system
documentation.
Not outputOutputNot
output
A copy pair cannot be made
because the specified S-VOL does
CB9E
not support either one or both of
the following:
The timestamp transfer mode
The Open/MF Consistency
Preservation Function
Not outputOutputNot
output
A copy pair cannot be made
because the specified P-VOL is not
a P-VOL for Cnt Ac-J Z.
CBD8
Not outputOutputNot
output
A copy pair cannot be created
because the specified S-VOL
CBD9
satisfies one of the following
conditions:
The S-VOL is being used for
FlashCopy.
The S-VOL is being used for
FlashCopy SE.
The S-VOL is a TSE-VOL.
Not outputOutputNot
output
A Cnt Ac-S Z copy pair cannot be
made because the mirror ID of Cnt
CBDC
Details of Error Codes 217