Table 66 Details of Error Codes EBxx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
of the primary storage system
does not match the actual serial
number or SSID of the primary
storage system.
Not outputOutputNot outputA Cnt Ac-J Z copy pair status
cannot be changed because the
EB3D
specified serial number or SSID
of the secondary storage system
does not match the actual serial
number or SSID of the secondary
storage system.
Not outputOutputNot outputA delta resync pair cannot be
made. The reason might be one
of the following:
EB48
The P-VOL of a Cnt Ac-S Z
copy pair and another P-VOL
of a Cnt Ac-J Z copy pair do
not match.
The storage system serial
number on the copy source is
incorrect.
Not outputOutputNot outputA delta resync pair cannot be
made because the delta resync
EB49
function is not supported in the
RCU.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified R-JNL
group is not registered.
EB4C
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified
EB4D
M-JNL group is not registered in
the storage system.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the timer type for
EB4F
M-JNLG differs from that for
R-JNLG.
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified
volume is not installed.
EB50
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified
S-VOL has PIN data.
EB51
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified
S-VOL cannot be accessed.
EB52
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the specified
S-VOL is blocked.
EB53
Not outputOutputNot outputA Cnt Ac-J Z copy pair cannot be
made because the status of the
cache is abnormal.
EB56