Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
Copy group monitoring status (ACTIVE or
INACTIVE)
cgsastat
Copy group startup status to be checked when
BCM Monitor starts
cgsaact
Startup action executed if the copy pair status
for starting BCM Monitor is different from the
specified startup status
cgsaopt
Option information of the CGSTARTUPSTATUS
parameter
status action err-action
Status, action, and error action for the copy
group specified in STATUS and ACTION
These parameters appear a specified number of
times.
The license key was installed.The license key has been
installed
YK9001I ISPF
An error occurred with the license information dataset.An error occurred in the
license information dataset
YK9051E ISPF
Check that the prefix of the license information dataset is registered
correctly, and that the license information dataset is created
correctly. If necessary, recreate the license information dataset and
re-register the license keys in the order in which they were issued.
For details about registering a prefix name of the license information
dataset, see the HP P9000 for Business Continuity Manager
Software Reference Guide.
An error occurred with the license key dataset.An error occurred in the
license key dataset
YK9052E ISPF
Check that the dataset name of the license key dataset is correct,
and that the license key dataset is created correctly. If necessary,
transfer the license key file again and recreate the license key
dataset.
An attempt was made to install a license key, but no installation
license key was found in the license key dataset.
A license key was not foundYK9071W ISPF
Make sure that none of the following conditions exist:
The license key you attempted to install was already installed.
The license key you attempted to install was not for this product.
The dataset you specified was not a license key dataset.
An attempt to install the license key has failed.The license key could not be
installed.
YK9072W ISPF
Check if one of the following conditions is applicable. If none is
applicable, make sure the key code is correct:
The license key you attempted to install was already installed.
The license key you attempted to install was not for this product.
The dataset you specified was not a license key dataset.
The license (function) has expired.The expiration date for your
license key (function).
YK9080E CON
List of Messages 27