Table 4 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKD0x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
One or more devices in the HP XP 256 Disk Array storage system
do not support TCA copy groups.
Some pairs in this group do
not support Hitachi
YKD058E MSG
SC=36 RC=48
Check that the command can be executed on this copy group, and
then re-execute the command.
TrueCopy™ Asynchronous
for Mainframe (TCA)
services.
The YKDELETE command terminated with the return code nnnn
and the reason code rrrr.
YKDELETE command return
code=nnnn, reason
code=rrrr
YKD099I TSO
This message is always displayed to indicate the return code and
the reason code.
nnnn
Maximum among the severity codes returned
during command execution
Table 5 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKE0x)
Explanation and Recommended ActionsMessage TextMessage ID
Invalid parameters are specified.Supplied parameters invalidYKE000T TSO
RC=48
For details, see the reason code in the YKE099I message that will
appear after this message. For reason codes, see IKJPARS in the
TSO/E Programming Services.
Nothing is assigned to the GOTO parameter.GOTO() not suppliedYKE001E MSG
SC=48 RC=48
Nothing is assigned to the MSG parameter.No message MSG() suppliedYKE001E TSO
RC=48
Nothing is assigned to the STEM parameter.No results STEM() suppliedYKE001E MSG
SC=48 RC=48
Nothing is assigned to the TIMEOUT parameter.TIMEOUT() not suppliedYKE001E MSG
SC=48 RC=48
Processing is terminating because the timeout limit has expired.Timeout limit has expired,
waiting for group
YKE001W MSG
SC=4 RC=4
Correct the timeout value or check that the status to be monitored
is correctly specified. Use the YKQUERY command to check the
copy-group to reach state
state.
status of the copy pairs. If there is a copy pair where a transition
has not taken place, the S-VOL of that copy pair might be ONLINE.
Make it OFFLINE and re-execute.
copy-group
Copy group ID
state
Status to be monitored
The last character of the STEM parameter is not a period.Copy Group STEM(stem)
does not include trailing "."
YKE002E MSG
SC=48 RC=48
stem
Stem name assigned to the STEM parameter
The value assigned to the DEVN parameter is invalid.DEVN() value invalidYKE002E MSG
SC=48
The last character of the MSG parameter is not a period.Messages MSG(stem) does
not include trailing "."
YKE002E TSO
RC=48
stem
List of Messages 35