HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
No copy pair is defined in the pair information CSV file. No data
was written in the copy group definition file.
No copy pair is defined in
specified Pair information
CSV file.
YKJ202I TSO RC=4
The number of items specified on one line of the pair information
CSV file is incorrect.
The number of items
specified for a line in Pair
YKJ203E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
information CSV file is
invalid: dd-name: rec#
rec#
Number of the line in the file identified by
dd-name where the error was detected
No P-VOL is specified in the pair information CSV file.Primary volume is not
specified in Pair information
CSV file: dd-name: rec#
YKJ204E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No S-VOL is specified in the pair information CSV file.Secondary volume is not
specified in Pair information
CSV file: dd-name: rec#
YKJ205E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The specified volume does not exist in the disk configuration
definition file.
The specified volume does
not exist in the disk
YKJ206E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
configuration definition file:
dd-name: rec#: device
rec#
Number of the line in the file identified by
dd-name where the error was detected device
One of the following is displayed. If both are specified, the device
number is displayed.
Device number
Storage system serial number, CU number, and command control
address number
The display format is
storage-system-serial-number:CU-number:CCA-number.
The P-VOL specified with the device number differs from the P-VOL
specified with the storage system serial number, CU number, and
command control address number.
Inconsistencies exist among
the values used to specify
the primary volume:
dd-name: rec#
YKJ207W TSO
RC=8
Although the copy group definition file was created, the settings
therein might contain an error.
dd-name
DD name of the CSV file where the error was
detected
52 Messages