HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
The serial numbers of the primary site storage systems are the same;
the serial numbers of the secondary site storage systems are
different; and copy pairs with an equal C/T group ID exist.
and a C/T group ID is used
for multiple CAJ Copy
Groups: dd-name: rec#
The serial numbers of the primary site storage systems are different;
the serial numbers of the secondary site storage systems are the
same; and copy pairs with an equal sub C/T group ID exist.
If the copy type is Cnt Ac-J Z, these combinations are not supported.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The volume specified as the S-VOL is also specified as the S-VOL
for other copy pairs. The same volume cannot be specified as the
S-VOL for multiple copy pairs.
Secondary volume is already
specified in another copy
pair as a secondary device:
dd-name: rec#
YKJ213E TSO
RC=32
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
A copy pair capacity check could not be performed because the
capacity of a volume could not be acquired. A capacity check
cannot be performed in either of the following cases:
A copy pair capacity check
could not be performed
because the capacity of a
volume could not be
acquired.
YKJ214W TSO
RC=8
Volume capacities were not acquired during a Local Scan.
The volume is a remote volume or a Non Gen'ed volume.
A copy group definition file was created, but the settings might
contain incorrect information.
The capacities of the copy pair volumes are different. A copy pair
whose P-VOL and S-VOL capacities are different cannot be defined.
The capacities of the copy
pair volumes are different:
dd-name: rec#
YKJ215E TSO
RC=32
To create a copy pair whose P-VOL and S-VOL capacities are
different for migration, specify NOCHECK for the CAPACITY
parameter, and execute the YKIMPORT command. For details, see
the HP P9000 for Business Continuity Manager Software Reference
Guide.
dd-name
The dd name of the CSV file where the error was
dectected.
rec#
Number of the line in the file indicated by
dd-name where the error was detected.
No value is assigned to the item identified by name in the EXCTG
information CSV file.
name is not specified in
EXCTG information CSV file:
dd-name: rec#
YKJ250E TSO
RC=32
name
Name of the item in the EXCTG information CSV
file
dd-name
54 Messages