Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM1x YKM5x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
The number of connections of inter-DKC paths of the same PathID
exceeded the maximum that is allowed within the same storage
system.
The number of connections of
inter-DKC paths of the same
PathID exceeds the maximum
YKM504E ISPF
number of connections that is
allowed within the same
storage system.
This inter-DKC path is already defined in another logical path.This inter-DKC path is already
defined in another logical
path.
YKM505E ISPF
In this interface version, the user cannot define inter-DKC paths.You cannot define inter-DKC
path with this interface version.
YKM506E ISPF
The number of connections of inter-CU paths exceeded the
maximum that is allowed within the same CU.
The number of connections of
inter-CU paths exceeds the
YKM507E ISPF
maximum number of
connections that is allowed
within the same CU.
This inter-CU path is already defined in another logical path.This inter-CU path is already
defined in another logical
path.
YKM508E ISPF
The number of physical paths exceeded the maximum that is
allowed within the same logical path.
The number of physical paths
that are defined in the same
logical path exceeds the limit.
YKM509E ISPF
This model does not support this path type.This Model is not supported for
this Path Type.
YKM510E ISPF
The number of CUs exceeds the maximum number for this model.The value of CU exceeds the
number of CUs that is allowed
in this Model.
YKM511E ISPF
The number of logical paths that are using this port exceeded
the limit.
The number of logical paths
that are using this port exceeds
the limit.
YKM512E ISPF
The number of connections exceeded the limit that is allowed
within this port.
The number of connections
exceeds the limit that is
allowed within this port.
YKM513E ISPF
A command control address could not be assigned because
the path is already defined in another logical path, or because
a list of command control addresses could not be obtained.
CCA could not be assigned
because either the path is
already defined in another
YKM514E ISPF
logical path, or the list of CCA
could not be retrieved.
The same serial number cannot be specified for both the primary
and secondary sides of the same logical path.
You cannot specify the same
serial number to the primary
YKM515E ISPF
side and the secondary side of
the same logical path.
The port errport is already defined as portdir.Port errport is already defined
as portdir port.
YKM516E ISPF
errport
The port that you specified
portdir
The port that is already defined
The value of PathID exceeds the maximum for this model.The value of PathID exceeds
the value that is allowed in this
Model.
YKM517E ISPF
72 Messages