Table 14 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM9x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
Execute the YKSTART command in an ISPF environment.
After that, you can execute whichever Business Continuity
Manager commands you need to.
The Business Continuity Manager load module was not found.
The Business Continuity Manager dataset might not be
concatenated to the LNKLST.
Load module is not found.YKM902E TSO
Revise the settings for the LNKLST, and then execute the
YKSTART command.
After that, you can execute whichever Business Continuity
Manager commands you need to.
The SELECT service terminated abnormally with the return code
nn.
SELECT service terminated
abnormally. RC=nn
YKM903E TSO
If this message is displayed immediately after executing the
YKSTART command, the Business Continuity Manager dataset
might not be concatenated to the panel library (dd name:
ISPPLIB), the table library (dd name: ISPTLIB), or the REXX exec
library (dd name: SYSEXEC).
If DBCS (Double-Byte Character Set) is enabled for the
environment, concatenate the Business Continuity Manager
dataset to the alternate panel library (dd name: ISPPALT). For
details, see the HP P9000 for Business Continuity Manager
Software Installation Guide.
nn
Return code of the service
The message library was not found.Message library was not
found.
YKM904E TSO
The Business Continuity Manager dataset might not be
concatenated to the message library (dd name: ISPMLIB).
If DBCS (Double-Byte Character Set) is enabled for the
environment, concatenate the Business Continuity Manager
dataset to the alternate message library (dd name: ISPMALT).
For details, see the HP P9000 for Business Continuity Manager
Software Installation Guide.
A GETMAIN error occurred. The program will stop running.A GETMAIN error occurred.YKM905E TSO
Contact technical support for assistance.
A FREEMAIN error occurred. However, the program will
continue to run.
A FREEMAIN error occurred.YKM906E TSO
Contact technical support for assistance.
Table 15 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKN0x)
Explanation and Recommended ActionsMessage TextMessage ID
Invalid parameters are specified.Supplied parameters invalidYKN000T TSO
RC=48
For details, see the reason code in the YKN099I message that
will appear after this message. For reason codes, see IKJPARS
in the TSO/E Programming Services.
Nothing is assigned to the MSG parameter.No message MSG() suppliedYKN001E TSO
RC=48
List of Messages 77