HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKT0x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
SVC number deletion failed in the SVCUPDTE macro.Couldn't delete SVC entryYKT007W CON RC=16
Contact technical support for assistance.
The YKALCSVC command was executed in the TSO/E
environment.
System task started without
START from TSO.
YKT008E CON RC=20
Execute the YKALCSVC command using the START
command or a batch job.
An error occurred in the Name/Token service.Name/token errorYKT012E CON RC=16
Contact technical support for assistance.
A value specified in the PARM parameter is invalid.Invalid parameterYKT021E CON RC=20
Check the specification of the PARM parameter.
The user SVC routine is already registered.SVC routine is already insertedYKT022E CON RC=4
The user SVC routine deletion failed.Couldn't delete SVC routineYKT023E CON RC=16
Contact technical support for assistance.
Copying of the load module failed. The program
abnormally terminates with user completion code 996.
Couldn't copy load moduleYKT024E CON
Contact technical support for assistance.
The user SVC routine is not registered or is deleted.SVC routine is already deletedYKT025E CON RC=4
The specified SVC number is already used. The program
abnormally terminates with user completion code 996.
SVC # is already usedYKT026E CON
Specify an unassigned SVC number in the PARM
parameter of the YKALCSVC command, or re-execute
without the PARM parameter.
The dataset name of the Business Continuity Manager
load library was not registered in SYS1.PARMLIB.
The task is not APF-authorized.YKT032E CON RC=20
Alternately, the execution of the command failed because
authorized/unauthorized datasets co-existed while
concatenating DD statements in the load library, and
they were handled as unauthorized datasets.
The user SVC routine deletion succeeded.SVC routine is deletedYKT098I CON RC=0
The user SVC routine registration succeeded.SVC routine is insertedYKT099I CON RC=0
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKT2x)
Explanation and Recommended ActionsMessage TextMessage ID
The command was invoked from the TSO/E
environment. The program stops processing.
System task started without START
from TSO.
YKT210E CON RC=8
Invoke the command using the START command, or
as a batch JOB.
A GETMAIN error occurred in CSA. The program stops
processing.
Failed to allocate space in CSAYKT211E CON RC=12
Contact technical support for assistance.
An error occurred during Name/Token registration.
The program stops processing.
Couldn't register Name/TokenYKT212E CON RC=12
Contact technical support for assistance.
88 Messages