HP P9000 for Business Continuity Manager Software Messages (T5253-96055, September 2011)

Table 29 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKX2x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
Nothing is assigned to the DEVN parameter.No device# DEVN() suppliedYKX201E MSG SC=48
Nothing is assigned to the MSG parameter.No message MSG() suppliedYKX201E TSO RC=48
Nothing is assigned to the SMODEL parameter.No model SMODEL() suppliedYKX201E MSG SC=48
Nothing is assigned to the STEM parameter.No results STEM() suppliedYKX201E MSG SC=48
Nothing is assigned to the SN parameter.No serial# SN() suppliedYKX201E MSG SC=48
Nothing is assigned to the SSN parameter.No serial# SSN() suppliedYKX201E MSG SC=48
The last character of the MSG parameter is not a
period.
Messages MSG(stem) does not
include trailing "."
YKX202E TSO RC=48
stem
Stem name assigned to the MSG
parameter
The last character of the STEM parameter is not a
period.
Results STEM(stem) does not
include trailing "."
YKX202E MSG SC=48
stem
Stem name assigned to the STEM
parameter
The specified parameter combination is invalid.Parameter combination is invalidYKX203E MSG SC=48
For details about the combination of parameters, see
the description of the YKQRYDEV command in the HP
P9000 for Business Continuity Manager Software
Reference Guide.
The device specified in the DEVN parameter does not
exist, or a device other than DASD or a PAV ALIAS
volume has been specified.
Device# DEVN() is not foundYKX204E MSG SC=48
The value specified in the CCA parameter is not in
hexadecimal format.
CCA() not valid hexYKX208E MSG SC=48
The value specified in the CU parameter is not in
hexadecimal format.
CU() not valid hexYKX208E MSG SC=48
The value specified in the DEVN parameter is not in
hexadecimal format.
DEVN() not valid hexYKX208E MSG SC=48
Access to the REXX variable identified by name failed.REXX failure return code=nnnn
starting with variable name
YKX210E TSO RC=40
For details about the return code, see IKJCT441 in the
TSO/E Programming Services.
nnnn
Error code returned upon REXX
access
The route list to be processed was not found.Necessary Route List is not found.YKX266E MSG SC=48
Review the ROUTE and DAD parameters, route list
definition file, and command device definition file you
specified when executing the YKLOAD command.
The YKQRYDEV command terminated with the return
code nnnn and the reason code rrrr.
YKQRYDEV command return
code=nnnn, reason code=rrrr
YKX299I TSO
98 Messages