HP P9000 for Compatible FlashCopy Mirroring User Guide (AV400-96388, October 2011)

Table 7 Compatible FlashCopy and Cnt Ac-S Z shared volume
Cnt Ac-S ZCompatible FlashCopy
R-VOLM-VOL
OKOKS-VOL
NOOKT-VOL
Volumes that cannot be shared:
The Compatible FlashCopy and Cnt Ac-S Z shared configuration is different from the IBM FlashCopy
and PPRC shared configuration. For Compatible FlashCopy and Cnt Ac-S Z, you cannot create
the following pairs (see “Compatible FlashCopy and Cnt Ac-S Z: Non-Sharable Combination
(page 23) ):
A Cnt Ac-S Z pair that includes a volume functioning as both a Compatible FlashCopy T-VOL
and a Cnt Ac-S Z R-VOL.
Figure 16 Compatible FlashCopy and Cnt Ac-S Z: Non-Sharable Combination
When you share Compatible FlashCopy S-VOL and a volume of Cnt Ac-S Z pair:
You must do the following when you share Compatible FlashCopy S-VOL and a volume of Cnt
Ac-S Z pair, or when you use the Remote FlashCopy function.
Specify only one Compatible FlashCopy-T-VOL if the Compatible FlashCopy S-VOL is shared
with Cnt Ac-S Z R-VOL.
Specify the volume of the same emulation type and same capacity with Compatible FlashCopy
S-VOL to Cnt Ac-S Z S-VOL if the Compatible FlashCopy S-VOL is shared with Cnt Ac-S Z
R-VOL.
Set the local mode (Mode 20 and Mode 190) to ON at RCU.
For details on how to set the local mode to ON, call the Support Center.
Use the volume whose emulation type is shown in Table 17 (page 29).
When you share the Compatible FlashCopy S-VOL and the volume of a Cnt Ac-S Z pair, the status
of the Cnt Ac-S Z pair must be either duplex, pending duplex, or suspend. However, if the shared
Cnt Ac-S Z volume is a R-VOL, there may be cases when you cannot create the Compatible
FlashCopy relationship (see the following table for detailed information).
Table 8 Volume Share of compatible FlashCopy S-VOL and Cnt Ac-S Z
Status of Cnt Ac-S Z PairShared Cnt Ac-S Z Pair Volume
SuspendPending DuplexDuplex
OKOK*1OKM-VOLCnt Ac-S Z
OKNo*2OKR-VOL*3
*1: If a Cnt Ac-S Z M-VOL is in pending status and you execute an ICKDSF command for Compatible FlashCopy, the
ICKDSF job will end abnormally with CC=12 error. For information on how to avoid that abnormal ending, see section
“Requirements of Compatible FlashCopy SE” (page 103).
Interoperability With Other products and functions 23