HP P9000 Provisioning for Mainframe Systems User Guide (AV400-96369, October 2011)
DescriptionItem
User-defined pool threshold values, in %.User-Defined threshold (%)
• Warning: The value defined for the Warning Threshold.
• Depletion: The value defined for the Depletion Threshold.
For a Snapshot pool, a hyphen (-) appears for Depletion.
Subscription limit, in %, of the pool.Subscription Limit (%)
The subscription limit is the ratio (%) of the V-VOL capacity that can be configured
to the total capacity of the pool volume. You cannot configure the V-VOL capacity
to exceed the subscription limit. For example, if the pool volume capacity is 100
GB and the subscription limit is 150%, you can configure up to 150 GB of the
capacity of V-VOL.
Number of the pool-VOLs in the pool.Number of Pool VOLs
Information about Smart Tiers.Smart Pool
• Tier Management: A hyphen (-) appears.
• Cycle Time: A hyphen (-) appears.
• Monitoring Period: A hyphen (-) appears.
Size of the buffer space in use for new page assignments on each tier.Buffer Space for New page
assignment (%)
Size of the buffer space in use for tier relocation on each tier.Buffer Space for Tier relocation (%)
• Tier 1: A hyphen (-) appears.
• Tier 2: A hyphen (-) appears.
• Tier 3: A hyphen (-) appears.
Opens the Pool Properties window when a pool is selected, and opens the error
window when a pool is not selected or multiple pools are selected.
Detail button
Deletes the pool selected in the Selected Pools window.Remove button
Opens the error window when a pool is not selected.
Click Next to go to the task setting window, which is indicated in Task Next
Option.
Next Task Option
Confirm window
Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.
Information in this topic assumes only a single task is performed. If performing multiple tasks, the
window shows all configuration items. To check information of a configuration item, click Back to
return to the configuration window, and then click Help.
160 Thin Provisioning Z GUI reference