However, step 1 is different. From the intermediate site, execute the YKDELETE command for the
Continuous Access Journal Z copy pair between the intermediate site and the remote site.
Recovering
For details about the recovering procedure required when a path failure occurs between the storage
systems at the primary site and the intermediate site, see the recovery procedure used when a
nonvolatile failure occurs in the intermediate site storage system. For details, see “Recovering”
(page 346) in “Operating procedure during an intermediate site storage system failure (nonvolatile)”
(page 345).
However, there is no need to perform step 2.
Operating procedure during a path failure between the storage systems at the
intermediate site and the remote site
The following are the operating procedures that must be performed when a path failure occurs
between the storage systems at the intermediate site and the remote site.
Preparing
If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same preparatory procedure that is used when a nonvolatile failure occurs in the
remote site storage system. See “Preparing” (page 349) in “Operating procedure during a remote
site storage system failure (nonvolatile)” (page 349).
Recovering
If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same recovery procedure that is used when a nonvolatile failure occurs in the remote
site storage system. See “Recovering” (page 350) in “Operating procedure during a remote site
storage system failure (nonvolatile)” (page 349).
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration
The following table explains how to perform maintenance for a 3DC Multi-Target (Cnt Ac-J Z x Cnt
Ac-J Z) configuration and how to take action if a failure occurs.
For maintenance or troubleshooting for the primary site storage system, either of the two remote
sites can be selected as the failover destination. If a primary site storage system failure occurred,
you can view the consistency time of each Continuous Access Journal Z copy pair to select the site
that has the latest data update time as the failover destination.
Table 101 Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration
See:DescriptionTargetMaintenance
or failure
No.
“Performing
primary site
Create a Continuous Access Journal Z copy
pair between remote sites 1 and 2, and then
Primary site storage system maintenanceMaintenance1
storage systemchange the configuration to a 2DC
maintenance”
(page 355)
configuration (Remote 1 → Remote 2, or
Remote 2 → Remote 1).
“Performing
storage system
Suspend the Continuous Access Journal Z
copy pair between the primary site and the
Storage system maintenance for remote site
1 or remote site 2
2
maintenancemaintenance-target remote site, and then
for remote sitechange the configuration to a 2DC
1 or 2”
(page 361)
configuration consisting of the primary site
and the other remote site.
“Performing
primary site
Delete the Continuous Access Journal Z copy
pair between the primary site and the remote
Primary site host maintenance3
hostsite that is not the failover destination, and
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 353