HP XP P9000 RAID Manager Installation and Configuration User Guide (T1610-96046, August 2012)

oradb2 oradev22(R) (CL1-D , 2, 2-1)30053 269..SMPL ----,----- ---- -
oradb oradev2(R) (CL1-D , 2, 2) 30053 269..S-VOL PAIR,----- 267 -
Configuration definition for cascading volume pairs
The RAID Manager software (HORCM) is capable of keeping track of up to seven pair associations
per LDEV (1 for Cnt Ac-S/Cnt Ac-J, 3 for Cnt Ac-J, 3 for BC/Snapshot, 1 for Snapshot). By this
management, RAID Manager can be assigned to seven groups per LU that describes seven mirror
descriptors for a configuration definition file.
Figure 25 Mirror descriptors and group assignment
Correspondence of the configuration file and mirror descriptors
The group name and MU# which are described in HORCM_DEV of a configuration definition file
are assigned the corresponding mirror descriptors, as outlined in Table 18 (page 84). “Omission
of MU#” is handled as MU#0, and the specified group is registered to MU#0 on Business Copy
and Continuous Access Synchronous. Also, the MU# that is noted for HORCM_DEV in
Table 18 (page 84) reflects a random numbering sequence (for example, 2, 1, 0).
Table 18 Mirror descriptors and group assignments
Continuous
Access
Business Copy
(Snapshot) only
MU#0HORCM_DEV parameter in configuration file
Journal
only
MU#1-#3MU#1-#2Business CopyContinuous
Access
(MU#3-#63)
Synchronous/
Continuous
Access
Journal
--oradev1oradev1HORCM_DEV
#dev_group dev_name port# TargetID
LU# MU#
Oradb oradev1 CL1-D 2
1
-oradev11oradev1oradev1HORCM_DEV
oradev21#dev_group dev_name port# TargetID
LU# MU#
Oradb oradev1 CL1-D 2
1
Oradb1 oradev11 CL1-D 2
1 1
Oradb2 oradev21 CL1-D 2
1 2
84 Sample configuration definition files