Hitachi Dynamic Link Manager Software Users Guide for Windows (7.6)

Displayed item
Description
No
summary
displayed
Summary
displayed
When a virtual ID is not used, a hyphen (-) is
displayed.
Physical-
iLU
- When a path is migrated using a virtual ID, displays
LU number in the storage system that is connected
by the migration-destination path.
For HUS VM indicated by a hexadecimal
number. The first two characters of iLU are the
CU number, and the last two characters are the
internal LU number within the CU.
For Hitachi Virtual Storage Platform, indicated
by a hexadecimal number. The first two
characters of iLU are the number of the logical
DKC (Disk Controller), the middle two numbers
are the CU number, and the last two characters
are the internal LU number within the CU.
When a virtual ID is not used, a hyphen (-) is
displayed.
Physical-
ChaPort
- When a path is migrated using a virtual ID, displays
port number of the CHA that is connected by the
migration-destination path.
When a virtual ID is not used, a hyphen (-) is
displayed.
-
Paths
Total number of the paths recognized by HDLM for
the LU to be displayed.
-
OnlinePaths
Number of online paths among the paths recognized
by HDLM for the LU. When the value of Paths is
equal to the value of OnlinePaths, all paths are
online. If the value of OnlinePaths is less than that
of Paths, some paths may have an error status, in
which case you should check the status of individual
paths and take resolve the problem for any paths
that have an error status.
Legend:
- : Not displayed
#1
This information is displayed when one of the following conditions exist:
- The user selected the item to be displayed by using the -lu -item
parameter.
- all was specified.
- No value was specified for the parameter.
#2
This information is displayed when one of the following conditions exist:
6-70
Command Reference
Hitachi Dynamic Link Manager User Guide for Windows
®