HP StorageWorks P9000 Replication Manager Software 7.1.1 Release Notes

Fixes
When there were multiple primary volume configuration definition files for a single secondary
volume configuration definition file, some of the primary volume configuration definition files
might not appear in the hosts view or pair configurations view.
An attempt to delete a task might fail with the KAVN00551-E (RPM-00456) message.
If a single copy group contained 256 or more Simplex (SMPL) copy pairs, to start Change Pair
Status Wizard for that copy group might fail with the KAVN00433-E (RPM-00480) message.
Tasks that create remote copy pairs failed with the KAVN00469-E (RPM-03304) message.
If copy groups that made up a multi-target or cascade configuration contain a different number
of pairs, Pair Configuration Wizard failed with the KAVN-00209-E message for copy pair
volumes in the copy group with less pairs.
Selecting a volume with multiple copy pair definitions and then starting Pair Configuration
Wizard failed with the KAVN00561-E(RPM-00063) message.
If there was an iSCSI-connected LU on the pair management server, when an attempt was
made in Pair Configuration Wizard to perform a pair operation task for a copy group, the task
might fail. In addition, alerts might not be detected, or the My Copy Group display might be
incorrect.
If there was an iSCSI-connected LU on the pair management server, when a create operation
that reverses the copy direction was executed in Pair Configuration Wizard, the task
succeeded but the result was not reflected in the Configuration Information window.
If the task to create a replica for the SQL Server database or the command (CLI) to make a
backup of the database failed with the KAVX1212-E message, the pair status might not change
to PSUS status and might remain in the PAIR status when the task or command (CLI) ends.
When the user attempted to open the JNLGs tab for the Continuous Access Journal secondary
storage systems in a 3DC delta resync configuration, if the resource group to which the user
belonged did not contain a Continuous Access Journal primary storage system, the attempt to
display the JNLG list tab might fail with the KAVN00209-E message.
If Reverse Copy Direction option was enabled for a create operation in Change Pair Status
Wizard, when the task for that operation was run for a copy pair that was part of a copy group
whose configuration definition files for the primary volume and secondary volume were located
on separate pair management servers, the task failed with the RPM-00500 message.
In a mainframe-based system, when selecting a copy pair that contained a volume for an
XP24000 or XP20000 storage system, if the Replication Manager registered the Device
Manager that contained information about the volume to the information source, Apply
Open/MF CTG option did not appear on 3. Select Pair Operation in Change Pair Status
Wizard.
In an environment in which 3DC MxNxO was configured on a mainframe system, you could not
add a consistency group to a copy group container.
If the primary and secondary volumes of a remote copy pair had the same LDEV number,
when you tried to created or perform operations on a copy pair, it failed with the RPM-00506
message, and the copy pair status of the secondary volume became Unknown.
Execution of a task that added a copy pair to an existing copy group that had a CTGID failed
with the KAVN00453-E (RPM-04601) message.
When you selected multiple volumes in Host view or Storage System view of LUNs, and then
you tried to start Pair Configuration Wizard, it might fail with the KAVN00561-E (RPM-00023)
message.
When you selected multiple volumes in Host view of DEVNs - Paired or Storage System view
of LDEVs- Paired, and then you tried to start Pair Configuration Wizard, it might fail with the
KAVN00561-E (RPM-00023) message.
Display of the Copy Groups page in the Hosts view might fail with the KAVN00419-E(RPM-
00590) message.
4