HP StorageWorks P9000 Replication Manager Software 7.1.1 Release Notes
Fixes
• When there were multiple primary volume configuration definition files for a single secondary
volume configuration definition file, some of the primary volume configuration definition files
might not appear in the hosts view or pair configurations view.
• An attempt to delete a task might fail with the KAVN00551-E (RPM-00456) message.
• If a single copy group contained 256 or more Simplex (SMPL) copy pairs, to start Change Pair
Status Wizard for that copy group might fail with the KAVN00433-E (RPM-00480) message.
• Tasks that create remote copy pairs failed with the KAVN00469-E (RPM-03304) message.
• If copy groups that made up a multi-target or cascade configuration contain a different number
of pairs, Pair Configuration Wizard failed with the KAVN-00209-E message for copy pair
volumes in the copy group with less pairs.
• Selecting a volume with multiple copy pair definitions and then starting Pair Configuration
Wizard failed with the KAVN00561-E(RPM-00063) message.
• If there was an iSCSI-connected LU on the pair management server, when an attempt was
made in Pair Configuration Wizard to perform a pair operation task for a copy group, the task
might fail. In addition, alerts might not be detected, or the My Copy Group display might be
incorrect.
• If there was an iSCSI-connected LU on the pair management server, when a create operation
that reverses the copy direction was executed in Pair Configuration Wizard, the task
succeeded but the result was not reflected in the Configuration Information window.
• If the task to create a replica for the SQL Server database or the command (CLI) to make a
backup of the database failed with the KAVX1212-E message, the pair status might not change
to PSUS status and might remain in the PAIR status when the task or command (CLI) ends.
• When the user attempted to open the JNLGs tab for the Continuous Access Journal secondary
storage systems in a 3DC delta resync configuration, if the resource group to which the user
belonged did not contain a Continuous Access Journal primary storage system, the attempt to
display the JNLG list tab might fail with the KAVN00209-E message.
• If Reverse Copy Direction option was enabled for a create operation in Change Pair Status
Wizard, when the task for that operation was run for a copy pair that was part of a copy group
whose configuration definition files for the primary volume and secondary volume were located
on separate pair management servers, the task failed with the RPM-00500 message.
• In a mainframe-based system, when selecting a copy pair that contained a volume for an
XP24000 or XP20000 storage system, if the Replication Manager registered the Device
Manager that contained information about the volume to the information source, Apply
Open/MF CTG option did not appear on 3. Select Pair Operation in Change Pair Status
Wizard.
• In an environment in which 3DC MxNxO was configured on a mainframe system, you could not
add a consistency group to a copy group container.
• If the primary and secondary volumes of a remote copy pair had the same LDEV number,
when you tried to created or perform operations on a copy pair, it failed with the RPM-00506
message, and the copy pair status of the secondary volume became Unknown.
• Execution of a task that added a copy pair to an existing copy group that had a CTGID failed
with the KAVN00453-E (RPM-04601) message.
• When you selected multiple volumes in Host view or Storage System view of LUNs, and then
you tried to start Pair Configuration Wizard, it might fail with the KAVN00561-E (RPM-00023)
message.
• When you selected multiple volumes in Host view of DEVNs - Paired or Storage System view
of LDEVs- Paired, and then you tried to start Pair Configuration Wizard, it might fail with the
KAVN00561-E (RPM-00023) message.
• Display of the Copy Groups page in the Hosts view might fail with the KAVN00419-E(RPM-
00590) message.
4