HP StorageWorks Disk Array XP operating system configuration guide: SGI IRIX (A5951-96075, December 2005)

CAUTION:
Do not change partitions 8, 9, or 10. Set the partitions (except partition
10) so as n ot to partition on top of another partition. Because partition 8
usually uses parts between 0 and 6, set the base of the rst partition to 6.
Fibre Channel
For connecting to a fabric switch, specify the device le directly:
# fx -x -d /dev/rdsk/50000e10ff809999/lun2vol/
c8p50000e10ff809999
Example
fx version 6.
5, Jan 11, 2000
...openin g /dev/rdsk/50000e10ff809999 /lun2vol/c8p50000e10ff809999
...drive sel ftest...OK
Scsi drive t
ype == HITACHI OPEN-3 5245
----- please choose one (? for h elp, .. to quit this menu)-----
[exi]t [d]
ebug/ [l]a be l/ [a]uto
[b]adbloc k/ [exe]rcise / [r]epartition/
fx> r
2. Use the pr tvtoc comm and to verify the partition c on guration as shown below:
# prtvtoc/dev/dsk/controller_device_targetID_LUN_partition#
Example
Disk Array XP operating system conguration guide: SGI I RIX
29