HP StorageWorks Disk Array XP operating system configuration guide: SGI IRIX (A5951-96075, December 2005)

2 Troubleshootin g
This section includes resolutions for various error conditions you may enc ounter.
If you are unable to resolve an error condition, ask your HP suppor t representative for
assistance. See Calling the HP suppor t center.
Error conditions
PCDATAcannotbei
nserted: Depending on your system conguration, you may be
able to view erro
rmessagesasfollows:
In Remote Web Console (Status tab)
In Command View Advanced Edition (“Aler ts” panel).
In Command Vie
w (Event History or Event Notic ation panels)
Error Condition Recommended Action
The logical devices are not recognized by the
host.
Verify that the READY indicator lights on the disk
array are ON.
Verify that ber c ables are correctly installed a nd
rmly connected.
Verify that the target IDs a re properly congured.
The LUNs for each TID must start at 0 and continue
sequentially without skipping any numbers.
Verify that the TIDs/W WNs on each b us are
unique.
Do not install two devices with the same ID on the
same bus.
Recheck the buses for new devices.Verify that LUSE
devicesarenotintermixedwithnormalLUNsonthe
same port.
Verify that the maximum number of LUSE devices
per port has not been exceeded.
Verify that the disk array host mode is set correctly.
The host
doesnotrebootproperlyafterhard
shutdow
n.
If you po
wer off the host without executing the
shutdow
n process, wait three minutes to allow
the dis
k array's internal timeout process to purge
queued commands. If the host restarts while the
disk array is processing queued commands, the
host m
aynotrebootsuccessfully.
Disk Array XP operating system conguration guide: SGI I RIX