HP StorageWorks Disk Array XP1024: Site Preparation Guide (A7906-96013, July 2005)
72 HP StorageWorks Disk Array XP1024: Site Preparation Guide
1. Environmental specification for operating condition should be satisfied before the disk
subsystem is powered on. Maximum temperature of 32ºC should be strictly satisfied at
the air inlet portion. The recommended temperature range is 21~24ºC.
2. Nonoperating condition includes both packing and unpacking conditions unless
otherwise specified.
3. On shipping/storage condition, the product should be packed with factory packing.
4. No condensation in and around the drive should be observed under any conditions.
5. The specifications apply to all three axes.
6. See ASTM D999-86, Standard Methods for Vibration Testing of Shipping Containers.
7. See ASTM D880-86, Standard Methods of Incline Impact Test for Shipping Containers.
8. See ASTM D775-80, Standard Methods for Drop Test for Loaded Boxes.
Specification Operating
1
Nonoperating
2
Shipping and
Storage
3
Temperature (°C) 16 to 32 –10 to +43 –25 to +60
Relative humidity (%)
4
20-80 8-90 5-95
Max wet bulb (°C) 26 27 29
Temperature deviation
(°C/hour)
10 10 20
Vibration
5
0.25 mm,
5-10 Hz
0.05 G,
10-300 Hz
2.5 mm,
5-10 Hz
0.5 G,
10-70 Hz
0.05 mm,
70-99 Hz
1.0 G,
99-300 Hz
0.5, 15 min.
6
at four most severe
resonances between
5-200 Hz
Shock 8 G, 15 ms
Horizontal:
7
incline impact: 1.22
m/s
Ve r ti ca l:
8
rotational edge: