HP StorageWorks Disk Array XP operating system configuration guide for Sun Solaris XP24000, XP12000, XP10000, SVS200, v01(A5951-96037, June 2007)

Figure 2 Point-to-point fabric topology example
Table 3 Fabric topology settings
ProvidesConnection parameterFabric parameter
FL-port (public loop) for loop connection to a
switch
FC-ALON
NL-port (private arbitrated loop)FC-ALOFF
F-port (fabric port) for connection to a switchPOINT-TO-POINTON
Not supportedPOINT-TO-POINTOFF
Installing and configuring the host
This section explains how to install and configure the host and host bus adapters (HBAs) that connect
the host to the disk array.
Loading the operating system and software
Follow the manufacturer's instructions to load the operating system and software onto the host. Load
all OS patches and configuration utilities supported by HP and the HBA manufacturer.
Installing and configuring the HBAs
Install and configure the HBA driver software and setup utilities according to the manufacturer's
instructions. Configuration settings specific to the XP array differ depending on the manufacturer.
Specific configuration information is detailed below.
WWN
The HBA configuration process may require you to enter the WWN for the array port(s) to which the
HBA connects. Your HP representative can provide you this information or you may display this
information on the SAN switch.
XP Disk Array Configuration Guide for Sun Solaris 17