HP StorageWorks Disk Array XP operating system configuration guide for Sun Solaris XP24000, XP12000, XP10000, SVS200, v01(A5951-96037, June 2007)

fca_nport = 1;
For a direct connect:
fca_nport = 0;
To enable failover for VxVM Dynamic Multi Pathing (DMP):
failover = 30;
For SAN persistent binding:
def_hba_binding = "null";
target20_wwpn="50060e8003285301";
target20_hba="fca-pci0";
target30_wwpn="50060e8003285311";
target30_hba="fca-pci1";
(Replace the WWPNs above with the WWPNs for your array ports.)
Edit the /kernel/drv/sd.conf file:
name="sd" class="scsi" target=20 lun=1;
name="sd" class="scsi" target=20 lun=2;
...
name="sd" class="scsi" target=30 lun=1;
name="sd" class="scsi" target=30 lun=2;
...
Perform a reconfiguration reboot to implement the changes to the configuration files.
If LUNs have been preconfigured in the /kernel/drv/sd.conf file, use the devfsadm command
to perform LUN rediscovery after configuring LUNs as explained in
Defining the paths” on page 25.
Clustering and fabric zoning
If you plan to use clustering, install and configure the clustering software on the servers.
Clustering is the organization of multiple servers into groups. Within a cluster, each server is a node.
Multiple clusters compose a multi-cluster environment. The following example shows a multi-cluster
environment with three clusters, each containing two nodes. The nodes share access to the disk array.
XP Disk Array Configuration Guide for Sun Solaris 23